Graphene Graphitization Furnaces, De-greasing Sintering Furnaces, Competitive Pricing
.jpg)

In Scope:
High-temperature graphitization furnace should mainly beFor sheet graphite, carbon material structural components (products)C/CComposite materials productsCarbonRaw materialsBattery negative electrode material high-temperature treatment, graphite powder high-temperature treatment, carbon fiber carbonization.High-temperature graphitization with other graphite materials. Other materials that can be sintered and melted in a carbon environment.
Advantages andFeatures:
1.High operating temperature, graphitizing furnace can reach in a short timeOperating Temperature Up to3000°C, Long-term Operating Temperature2500℃Please provide the Chinese content you would like to be translated into American English.2800℃;
2.The furnace features excellent sealing, a fully enclosed structure, equipped with a vacuum extraction system and an argon置换 system, ensuring the purity of the gas inside the furnace.
3.Energy-saving and power-efficient Electromagnetic induction heating is used to directly heat the graphite boat tray, ensuring high thermal efficiency and energy saving.
4.Rapid heating rate up to600℃/h(Lower temperature, faster.
5.Utilizing advanced infrared temperature measurement technology,PIDSegmented program controls the heating curve. Accurate temperature control with minimal error.
6.High safety level, featuring a double-layer stainless steel furnace shell, with water-cooled interlayer, the outer shell temperature of the furnace is lower than50With pressure, water pressure, and high-temperature alarms, equipped with an over-pressure venting device.
Specs and Parameters:
Parameter specifications | APD-SL-400 | APD-SL-500 | APD-SL-600 | APD-SL-800 |
Crucible Effective Volumemm) | Φ400x800 | Φ500x1100 | Φ600x1200 | Φ800x1200 |
Fill VolumeL) | 100 | 215 | 340 | 600 |
Power Supply Rating(KW) | 200 | 250 | 300 | 600 |
Heating Method | Medium-frequency induction heating | |||
Control Method | Silicon Controlled Rectifier (SCR)IGBTHand-operated+Automatic Control Method | |||
Ultimate vacuum degree(pa) | Chilled state20pa | |||
Typical Operating Temperature℃ | 2850 | |||
Short-term operating temperature available℃ | 3000 | |||
Constant temperature zone temperature difference℃ | ±15 | |||
Work atmosphere inside the furnace | Vacuum or inert gas protection (micro-positive pressure) | |||