Catch Net Equipment Analysis (2025 Updated Edition)
I. Core Advantages of the Catch Net
High Ball Collection Rate: Utilizes grid plate分流 design or funnel structure, achieving a ball collection rate of over 95%, avoiding issues such as ball leakage and ball loss.
Structure Optimization: Streamline components (e.g., eliminate small meshes, adjusting valves), enhance mesh rigidity and flow efficiency, reduce water resistance (≤250mmH₂O).
Operation Reliability: The grid plate can switch to "backwash" mode, automatically clearing debris and reducing water resistance, with the electric actuator providing precise positioning.
Versatile: Customizable for pipe diameters from DN300 to DN1200, suitable for retrofitting old units and new projects.
Section II: Customization Parameters Requirements
Type Selection
Grating Mesh Plates: SF Type (Dual Mesh Plates Diversion), SD Type (Single Mesh Plate).
Funnellike (SL type): Ideal for high flow rate and large volume applications._
Key Parameters:
Material: 304/316 stainless steel (corrosion-resistant), carbon steel (standard conditions).
Design Pressure: 0.6-1.0 MPa (adjustable according to circulating water system pressure).
Interface Specifications: Flange Standard HG/T20592-2009 PN16, Pipe Diameter Supported DN300-DN1200.
Drive Mode: Optional manual for DN300-DN700, standard intelligent electric actuator for DN800 and above.
Sample Product: Jiu Sheng Power Custom Catch Net (Model SN-800) from Lianyungang
Design Pressure: 1.0 MPa
Material: 304 Stainless Steel (optional carbon steel)
Interface Specification: DN800 (Customizable)
Reference Price: $3,500 - $8,000 (depending on configuration)
Product Details Link
III. Installation and Maintenance Precautions
Installation Specifications:
Location Requirement: To be installed on the outlet section of the condenser circulating water pipe, the lower flange elevation must be higher than the ball mill pump inlet elevation.
Drive Unit: Electric actuator requires pre-tensioned vibration prevention; after installation, test the flexibility of the screen change.
Straight pipe segment reserved: Length of straight pipe prior to import ≥ 1 times the diameter of the circulating water pipe (e.g., for DN800, a reserved straight pipe of 800mm is required)
Maintenance Points:
Regular inspections: Check for web plate deformation, soldering issues, and shaft movement flexibility quarterly, and promptly adjust or replace parts as necessary.
Backwash Operation: Switch to "Backwash" mode weekly to clean debris, monitor pressure difference (immediately address if > 250mmH₂O).
Catch Rate Monitoring: Test catch rate (≥95%) after commissioning; investigate screen plate alignment or rubber ball quality if not up to standard.
Four: Technical Support
Lianyungang Jiusheng Power offers free installation guidance and a 3-year warranty, with remote debugging services supported. Recommend pairing with their intelligent differential pressure monitoring system for real-time early warnings of blockage risks.