Full-Closed Dry Nitrogen Blower AYAN-DC16G
The Full-enclosed Automatic Nitrogen Blow-off Instrument is one of the new concentrated products jointly developed by our company and Zhejiang University of Technology, tailored to the laboratory's needs for convenience, safety, speed, and stability. The product, designed with ease of use and sample safety in mind, features 50-stage programmable temperature control, electrically adjustable height, high sample visibility, and high airtightness. It also incorporates multi-group data storage capabilities, ensuring a safe and convenient concentration process that is easily monitored and controlled. This makes the complicated concentration process flexible, hassle-free, efficient, and secure.
Product Features:
7-inch large LCD touch screen control, capable of handling 1-25 pieces of high-capacity samples simultaneously
2. Utilizes 5 modes with a 50-step temperature control program, offering high intelligence.
3. Utilizes dry heating method to prevent water vapor contamination of samples, ensuring their safety and accuracy.
4. The heating module is made of pure aviation aluminum, featuring fast and even heating, with the added benefit of being easily replaceable.
5. Modular four-side visualization, with a sample tray that features a drawer-style sliding mechanism for easy sampling. It allows for a corner-free observation of the liquid level, extremely convenient.
6. The blowing needle lift method features two modes: fine adjustment and quick lift, without the need for manual lifting.
7. Equipped with an automatic pressure regulating device, ensuring uniformity of air pressure across all gas lines.
8. Equipped with multiple data storage functions, allows for real-time viewing of machine operating data
9. Equipped with a double-sealed door mirror protection system and an internal recirculating fan system, no ventilation window is required, ensuring no volatile emissions leakage.
10. The case features two observation windows on the front and side, facilitating easy viewing of the sample condition.
11. Nitrogen preheating feature, the introduced gas is all heated air (temperature: around 45 degrees), which accelerates the concentration reaction of the sample and prevents condensation between the concentrated liquid and the blowing needle, ensuring that the sample is not contaminated or cross-contaminated.
12. Nitrogen preheating function and independent throttle solenoid control ensure gas circuit airtightness, significantly reducing nitrogen consumption.

What are the application solutions of nitrogen blowers in the detection industry?
1. Application of Nitrogen Blowout in Environmental Testing: Nitrogen blowout units can be used for sample pretreatment prior to gas chromatography (GC), particularly suitable for the analysis of volatile organic compounds (VOCs). In environmental testing, nitrogen blowout instruments can quickly remove solvents and other interfering substances from samples, reducing the burden on the GC column, and enhancing the accuracy and sensitivity of analytical results.
2. Application of Nitrogen Blow-Down in Food Safety Testing: Nitrogen blow-down instruments can be used for the analysis of harmful substances such as pesticide residues and food additives in food samples. By treating the samples with a nitrogen blow-down instrument, the concentration of the samples can be increased, facilitating subsequent analysis and testing.
3. Application of Nitrogen Blowout in Pharmaceutical Analysis: Nitrogen blowout instruments can be used for the analysis of impurities in pharmaceutical samples. Through the solvent removal process of the nitrogen blowout instrument, solvents and other impurities in the sample can be volatilized, thereby enhancing the sensitivity and accuracy of pharmaceutical analysis.
4. Applications of Nitrogen Blow-Down in Material Science Research: Nitrogen blow-down systems can be utilized for processes such as organic solvent removal and drying in material research. During the synthesis, characterization, and performance testing of materials, nitrogen blow-down systems can help enhance the purity and stability of samples, ensuring the reliability of subsequent experimental results.
In summary, nitrogen blowers are widely used in the detection industry, helping to enhance analysis accuracy, sensitivity, and efficiency, making them a crucial sample pretreatment instrument.
Full-Closed Dry Nitrogen Blower AYAN-DC16G
Product Specifications:
Model | AYAN-DC16G | AYAN-DC25G |
Display Method | 7-inch large LCD touch screen | 7-inch large LCD touch screen |
Pattern | 5 types | 5 types |
Programmable temperature control | 50 sections | 50 sections |
Sample Quantity | 16 bits | 25 pieces |
Module Diameter | 16mm (optional) | 16mm (optional) |
Visual Surface | 4 sides | 4 sides |
Timer function (min) | 0-999 | 0-999 |
Electric lifting method | 2 types | 2 varieties |
Pressure Regulation (MPa) | 0-0.8 | 0-0.8 |
Pressure Operation Method | 15 individually controlled | 25 individually controlled |
Temperature: °C | Room temperature -100℃ | Room Temperature (-100℃) |
Heating Method | Dry-type unified control | Dry Type Unified Control |
Temperature Control Accuracy: °C | ±1 | ±1 |
Over-temperature alarm | Available | Available |
Built-in exhaust fan system | Available | Available |
Double-sealed door system | Available | Available |
Timer function | Available | Available |
Method of Sampling | Drawer-style | Drawer-style |