Self-limiting electric heating tape, also known as self-regulating or self-controlled electric heating tape, autonomously adjusts the local heating power of the tape based on temperature changes under normal operating conditions.
As shown in the figure, after applying the working voltage, conductive particles in the semiconductor core strip form a current path between the busbars. As the temperature rises, the semiconductor core strip expands, reducing the current path and decreasing power; conversely, power increases. The conductive carbon particles in the semiconductor core strip are extremely small, and this regulating mechanism exists at every complete structure of the self-limiting temperature electric heating tape. Therefore, in applications where temperature control is not required, the self-limiting temperature electric heating tape can be used without a temperature controller; any trimming and connection within its usage length will not affect its heating structure, and it can be overlapped without causing overheating that damages the heating structure.

Structure Diagram of Medium-Low Temperature Self-Limiting Temperature Electric Heat Trace Tape
1. Self-limiting heating tape model specifications
Self-limiting heating cable
□: Rated Power W/m
Q: Reinforce outer sheath;
STL: Low Temperature Self-Limiting Electric Heating Tape
STH: Medium to High Temperature Self-Regulating Electric Heat Tape

High-Temperature Self-Limiting Heat Trace Cable
2. Main Technical Parameters of Self-limiting Heating Cable:
| Model | STL Type | STH Model | |
| Project | |||
| Temperature Grade | T6 | T4 | T2 |
| Temperature Resistance | 100℃ | 135℃ | 215℃ (20 bar saturated steam) |
| Rated Output Power (10℃) | 10/15/20/25/30/35W/m | 10/15/20/25/30/35/40/45/50/55/60/66 W/m | |
| Rated Voltage | 220V/380V | 220V/380V | 220V |
| Installation Temperature | ≥-30℃ | ≥-30℃ | ≥-60℃ |
| Bend Radius | 26mm at -20℃ | 26mm at -20°C | At 20°C, it measures 26mm. |
| -30°C at 31mm | -30°C at 31mm | -60℃ for 51mm | |
| Explosion-Proof Marking | Ex e IIC T4 Gb | ||
3. Self-limiting temperature electric heat trace power curve

Low-Temperature Self-Limiting Heating Cable Power Curve Graph

Medium-high temperature self-limiting electric tracing heating power curve graph

High-Temperature Self-Limiting Heat Trace Cable Power Curve Graph
4. Applicable Locations
Self-limiting heating cables are suitable for anti-freezing and anti-condensation protection of pipelines and equipment in the following situations:
·Safe Zone
· Hazardous Area 1, 2; Zones 21, 22;
·Moist and salt fog environments; corrosive environments (products with fluoride-sheathed cables).

Three-layer co-extruded self-limiting electric heating tape
This product incorporates our company's cutting-edge domestic technology, with its core technology being the one-time extrusion production of a conductor, a low-resistance transition layer wrapped around the conductor, a semiconductor core strip, and an inner insulation layer. The self-limiting temperature electric heating cable produced using the triple-squeeze technique benefits from the dense structure within the semiconductor core strip's inner insulation layer, reducing the impact of air, water, oil, and impurities on the various layers of the semiconductor core strip. This consequently minimizes the attenuation rate and starting current of the semiconductor core strip, enhancing the service life of the self-limiting temperature electric heating cable.