CUT-89HAll-Digital Multi-Channel Ultrasonic Flaw Detector
Instrument Introduction:
Features of Multi-Channel Ultrasonic Flaw Detector:
Compact, lightweight, and small in volume,
All-digital, self-owned intellectual property, powerful features,
Advanced circuit design and manufacturing technology ensure reliable performance and stable operation.,
High signal-to-noise ratio, strong defect resolution capability,
The gate alarm function is comprehensive with strong anti-interference capability.,
Multiple up to64 Channel,
Reserved Encoder,16 Enter/16 OutstandingI/O Interface,
The system configuration is simple and flexible to meet the requirements of more channels.,
High reliability, easy maintenance,
Based onwindows Platform, robust report document processing capabilities,
Self-developed control interface, user-friendly, and highly operable.,
Software modularization, configurable as needed,
Self-owned intellectual property, facilitating secondary development for users,
Custom application software can be designed for users to meet their specific requirements.,
RobustTCP/IP Communication Capabilities。
Features:
Automotive Industry:Spark plug testing, individual inspection of safety components
Aerospace Industry:Composite material testing, immersion and scanning inspections
Railway:Wheel and axle inspection
Power PlantWeld seam inspection, multi-channel defect detection, and wall thickness measurement
Metallurgical Industry:Cast Inspection
Steel Mill:Steel rail, steel bar, and steel pipe inspection
Research:Complex applications such as composite materials, powder metallurgy, joint connections, and material properties testing
Instrument Parameters:
1Instrument Type
AModel Pulse Ultrasonic Six-Channel flaw detector
2Repetition frequency
Single-channel repetition frequency can reach as per agreement20KHzGenerally attainable10KHz
3Continuous Operating Time
0~40℃Ambient temperature24 Hour
4Repetition Frequency
System operating frequency20HzIndividual channel repetition frequency can be set to10KHz-5KHz-2.5KHz-
1KHz-0.5KHz。
5Channel Operation Sequence
Two channels alternating operation
6Scanning Range:10~5000mm(Steel longitudinal wave), continuously adjustable
7Horizontal Linear Error: Less than1%
8Probe Operation Mode
Single probe transmission, reception, or dual probe transmission and reception separately
9Amplifier Frequency Band:0.5MHz-15MHz
10Gain:80dBIncrement0.1dB
11Non-destructive Testing Sensitivity:Greater than50dB
13Resolution:Greater than26dB
14Dynamic Range:Greater than30dB
15Vertical linear error:Not greater than5%
16Alarm
Each channel can be setA、B、C Three alarm doors
16.2Display Method
A horizontal bright lineBARThe horizontal axis represents time, while the vertical axis indicates the threshold.
16.3Alarm Method
Each alarm door can be individually set for incoming wave and lost wave alarms.
16.4Alarm door triggering method
ADoorsBDoor: Synchronous Trigger
CDoor: Synchronized triggering, tracking lock
16.5Relevant anti-interference
Relevant Times: Incoming Waves1~15 Secondly, wave loss:3~15 Each door can be separately set up.
16.6Please send alarm.
In-cabin sound alarm (three alarm doors have three different sounds), electrical pulse output
16.7Electrical pulse output
16.7.1 Electrical Pulse Performance
Each alarm door outputs separately.10-30Opto-electronic Isolation
16.7.2 Delay in shipment
Delay: Electrical pulses can be set for delayed output
Delinquency Time Setting:0~2 Second0.1 Instant step forward
17Interface Tracking
17.1Various channelsC Alarm door can be set to interface tracking door
17.2Track the interface door starting point, width, and threshold, all the same as the alarm door.
18Instrument Weight:Approx.15kg
19Instrument size:558mm×430mm×173mmPlease provide the Chinese content to be translated.×Wide×High (no Chinese content)
20Instrument is allowed for use in the following environments:
Storage Temperature: -20℃~+60℃
Operating Temperature:-15℃~+55℃
Relative Humidity:Not greater than90%
21Power supply:220V(±10V),50Hz
22Power Consumption:250W
Work Environment:
Operating Temperature:-15 ~ 55℃
Storage Temperature:-20℃ ~ +60℃
Relative Humidity:Not greater than90%
Working Voltage:AC220±10V
Inspection Detection Corner:

Inspection Corner: