Volumetric Gas Water Heater: BTR (BTRO) Series Commercial Condensing Low Nitrogen Volumetric Gas Water Heater
All-new condensing design, efficiency up to 105%
In traditional gas equipment, the latent heat of vaporization of water vapor in the high-temperature flue gas from combustion is not utilized. However, with a condensing容积式 gas water heater, advanced condensing technology is employed to cool the flue gas to 40-80°C, thereby fully utilizing the latent heat of vaporization of the water vapor. As a result, the heat output is increased by approximately 15% under the same input load.
Performance Features
High-efficiency energy-saving
Top-mounted fully premixed combustion, significantly enhancing combustion efficiency. Unique spiral heat exchanger, fully absorbing the latent heat of vaporization of water vapor in flue gas, achieving a thermal efficiency of up to 106.5%.
Easy installation
Two models (indoor unit, outdoor unit), compact size; can be connected for balanced exhaust ventilation without consuming indoor air.
Safe and reliable
Electrical spark ignition, low load start-up; featuring a four-level protection system including temperature controller, high-temperature limit, over-temperature protection, and temperature-pressure safety valve to ensure safe operation; pressure-bearing capacity up to 1.1 MPa.
Tackle pipeline water pressure fluctuations with ease.
Long service life
Optional 1: 316L stainless steel inner lining, 316L furnace tubes, 304 outer casing, food-grade stainless steel quality guaranteed, providing longer-lasting protection for the inner lining.
Optional Two: The main unit is fully vitrified, resistant to acidic and alkaline water quality, particularly anti-corrosive and anti-scaling, thereby extending the overall service life.
Option 3: Full-body hot-dip galvanizing for the main unit, with a mature and stable galvanizing process, cost-effective, and high cost-performance ratio.
Low Nitrogen Environmental Protection
Two emission options: standard and low NOx. The low NOx model emits less than 30mg/m³ of NOx, meets environmental standards, and is more environmentally friendly.

The Function and Principle of Air Conditioning Distributing and Collecting Headers
The function of the air conditioner condensate separator is to分流 and collect the condensate or waste water generated by the indoor air conditioner unit, and then discharge it. It operates by designing a special structure that allows water vapor or droplets to adhere to the surface of the separator, guiding the water flow into the lower drainage pipe, thereby preventing water droplets from falling indoors and causing unnecessary environmental pollution and damage. Below, I will elaborate on the function and principle of the air conditioner condensate separator.
Firstly, the function of the air conditioning condensate collector is to分流and collect condensate water or wastewater produced by the indoor unit of the air conditioner, and then discharge it. When the air conditioner is running, the indoor unit absorbs moisture from the indoor air through the air circulation system, and the moisture in the air condenses into water droplets during the cooling process, which are then drained out through the drainage pipes; or when there is a significant temperature difference between the inside and outside of the air conditioner, dew points form inside the unit, generating condensate water. These water droplets or condensate water then enter the condensate collector through the drainage pipes.
Secondly, the principle of the diverter is mainly to divert and collect condensate or water droplets from the indoor unit through the design of special structures and materials. Generally, a diverter consists of two parts: the collection section and the drainage section.
The water collection section is typically a concave structure, which is usually coated or made from a special material with superhydrophilic properties. This allows water droplets or condensation to rapidly spread across the surface, increasing the contact area between water and the surface, and causing them to quickly adhere to the water collector. As a result, the water droplets or condensation will not fall indoors, effectively preventing dripping.
The drainage section is designed to channel water droplets or condensation from the surface of the collector into the lower drainage pipe. Typically, this section consists of one or more water channels or ditches, which are shaped and sloped to guide the water droplets or condensation along the channel or ditch into the drainage pipe. Some collectors may also be equipped with filter meshes to trap impurities and debris in the water, preventing blockages in the drainage pipe.
In summary, the function of an air conditioner condensate separator is to分流 and collect or discharge condensate or wastewater generated by the indoor air conditioner unit. Its principle involves designing special structures and materials to adhere water vapor or droplets to the separator's surface, channeling the water flow into the lower drainage pipes, thereby preventing water droplets from falling indoors and causing unnecessary environmental pollution and damage. By using the air conditioner condensate separator properly, you can maintain clean and dry indoor air, enhancing the comfort of the indoor environment.