Volumetric Gas Water Heater
Volumetric Gas Water Heater: BTR (BTRO) Series Commercial Condensing Low Nitrogen Volumetric Gas Water Heater
New condensing design, efficiency up to 105%
In traditional gas equipment, the latent heat of vaporization in the high-temperature flue gases produced by gas combustion is not utilized. However, with a condensing容积式 gas hot water boiler, utilizing advanced condensing technology, the flue gases are cooled to 40~80℃, thereby fully utilizing the latent heat of vaporization of steam, resulting in a heat output increase of approximately 15% under the same input load.
Performance Features
High-efficiency energy-saving
Top-mounted full premixed combustion; significantly enhances combustion efficiency. Unique spiral heat exchanger, fully absorbs the latent heat of vaporization from the flue gas, achieving a thermal efficiency of up to 106.5%.
Easy installation
Two models (indoor unit, outdoor unit), compact in size; can be connected for balanced exhaust, without consuming indoor air.
Safe and reliable
Electrical spark ignition, low-load start-up; equipped with a temperature controller, high-temperature limit, over-temperature protection, and a temperature-pressure safety valve for quadruple protection to ensure safe operation; pressure-bearing capacity up to 1.1 MPa.
Cope effortlessly with fluctuating pipeline water pressure.
Long service life
Optional 1: 316L stainless steel inner tank, 316L furnace tubes, 304 outer tank, food-grade stainless steel quality assured, offering the inner tank enhanced durability protection.
Option 2: Whole host vitreous enameling, resistant to acidic and alkaline water, especially anti-corrosion and scale-resistant, extending the overall service life.
Option 3: The main body undergoes full hot-dip galvanizing, with a mature and stable galvanizing process, cost-effective, and high in performance-to-cost ratio.
Low Nitrogen Environmental Protection
Two emission options: standard and low NOx models. The low NOx model emits less than 30 mg/m³, meets environmental standards, and is more environmentally friendly.

The Function and Principle of Air Conditioning Zone Valves
The function of an air conditioner condensate separator is to分流 and collect condensate or wastewater generated by the indoor unit of an air conditioner, and to discharge it. Its principle involves designing a special structure to adhere water vapor or droplets to the surface of the separator, directing the water flow into the lower drainage pipe, thus preventing water droplets from falling indoors and causing unnecessary environmental pollution and damage. Below, I will provide a detailed explanation of the function and principle of the air conditioner condensate separator.
Firstly, the function of the air conditioner header and collector is to分流 and collect condensate water or waste water generated by the indoor unit of the air conditioner, and to discharge them. When the air conditioner is running, the indoor unit absorbs moisture from the indoor air through the air circulation system, and the moisture in the air condenses into water droplets during the cooling process, which are then drained out through the drainage pipes; or when there is a significant temperature difference between the inside and outside of the air conditioner, dew points form inside the unit, leading to condensate water. These water droplets or condensate water then enter the header and collector through the drainage pipes.
Secondly, the principle of the drain separator is mainly achieved through the design of special structures and materials, which分流and collect condensate or water droplets produced by the indoor unit. Generally speaking, the drain separator consists of two parts: the collection section and the drainage section.
The water collection section is typically a recessed structure, whose surface is often treated with a special coating or material that has superhydrophilic properties. This allows water droplets or condensation to rapidly spread across the surface, increasing the contact area between water and the surface, and causing the droplets or condensation to quickly adhere to the water collector. As a result, the water droplets or condensation will not fall indoors, effectively preventing dripping.
The drainage section consists of channeling water droplets or condensate from the collector surface into the lower drainage pipe. The drainage section typically features one or more water channels or ditches, designed with specific shapes and inclinations to guide the water droplets or condensate along the channels or ditches into the drainage pipe. Some collector assemblies are also equipped with filter meshes to trap impurities and debris in the water, preventing clogs in the drainage pipes.
In summary, the function of an air conditioner condensate separator is to分流 and collect condensate or wastewater from the indoor unit of an air conditioner. It operates by designing special structures and materials to adhere water vapor or droplets to the separator's surface, channeling the water flow into the lower drainage pipe. This prevents water droplets from falling inside, thus avoiding unnecessary environmental pollution and damage. Proper use of the air conditioner condensate separator helps maintain clean and dry indoor air, enhancing the comfort of the indoor environment.