1、 Product Name and Model
1.1 Product Name | Insulated glassUltraviolet (UV) Radiation Test Chamber |
1.2 Model No. | ZK-Z/02 |
2、 Principle of the Test Box | |
This test evaluates the hollow glass's resistance to ultraviolet radiation. After irradiation, if there are volatile substances like organic matter, water, or oil in the sealing adhesive, they can be adsorbed onto the inner surface of the glass through a cooling water tray. It also checks the creep of the sealant strip under ultraviolet radiation.Situation. | |
3、 Basic Product Parameters | |
3.1 Nominal Cubic Content 3.2 Inner box size 3.3 Dimensions (approx.) 3.4 Temperature Range 3.5 Light Source 3.6 Output Power 3.7 Sample center distance from light source 3.8 Maintain imported water temperature 3.9 Outflow water temperature 3.10 Copper Cooling Plate 3.11 Test Cycle 3.12 Noise Index 3.13 Load 3.14 Water Heating Power 3.15 Compressor Power 3.16 Pump Power 3.17 Equipment meets standards. 3.18 Temperature Control | 0.175m3 560×560×560 (width×depth×height mm) 870×650×1,200 (W×D×H mm) excludes projections 50℃±3℃ MLU/300W, 220V voltage±5V ≥40W/㎡ 300mm 16℃±2℃ Not to exceed 2 degrees above the water inlet temperature℃ 150mm, 2 pieces 168h ≤70db 2 pieces of glass (360×510mm) ≤1kw 1/3 hp x 1 unit (Teka, France) 60W GB11944-2012 "Insulating Glass" Ensure the temperature inside the test chamber is 50±3℃, |
3.19 Image (for reference only) | |
4、 Structural Features | |
4.1 Structural form | The test chamber features an integrated structure, with the upper section serving as the work area, the lower section as the refrigeration unit, and the right side as the electrical control cabinet. |
4.2 Structural Features | Inner lining is made of1.2mmSUS304Stainless steel sheet, housing in1.5mmCold rolled steel, with machinery and cabinet frame structure4#Angle iron The cabinet is laser-cut./Numerical Control Machining, Imported from France: AkzoNobel Powder, GermanyWagnerAutomated coating lines spray plastic on steel plates internally and externally to enhance the product's lifespan. The test box features an upward-opening lid structure for the door. |
4.3 Heating System | The heater utilizes a stainless steel electric heating tube, with a total of 1 tube installed. Heating element control method: Non-contact, etc., cyclic pulse width modulation, SSR (Solid State Relay) |
4.4 Recirculation method | The pump circulates water from the reservoir through the cooling unit, continuously adjusting the reservoir's water temperature according to the test program requirements. |
4.5 Trial samples and sample holders | Sample Sheets: 360×510mm, 2 pieces Sample Stand: Made of stainless steel tube (with insulation device) Equipped with a glass limit device, made of non-metallic materials |
4.6 Cooling System 4.7 Spray Irrigation System 4.8 Bottom frame drainage 4.9 System adjustment method | Utilizing refrigeration compressor units (Thermokon high-temperature compressors from France) Comply with GB11944-2012 and relevant standards Easy drainage Utilize balanced temperature regulation method |
5、 Refrigeration System | |
5.1 Compressor 5.2 Cooling unit control method
| Utilizing one full-seal refrigerator compressor from France's Tecumseh for a single-stage air-cooled unit. The control system automatically adjusts the operating conditions of the refrigeration unit based on test conditions and monitors its operation. |
5.3 Refrigerant 5.4 Condenser Condensing Evaporator | Utilizing environmentally friendly refrigerants Shell and tubeHeat Exchanger Finned heat exchanger |
5.5 Cooling evaporator | Utilizing copper coil, positioned within the water tank of the test box |
6、 Electrical Control System | |
6.1 Temperature Control Instrument
6.2 Sensor 6.3 Execute electronic components
6.4 Control Instrumentation Section |
Pt100 Platinum Resistance Element Schneider contactors and residual current protectors from FranceIntegratedBrand Solid State Relay This control system meets the functional requirements of climate cycle test chambers, including: 1) Automatically completes the UV radiation resistance test for hollow glass as specified in GB11944-2012. 2) Automatic temperature control 3) Real-time display of test data. |
7、 Safety Protection Device | |
7.1 Test Chamber | Total power phase sequence and phase failure protection Leakage Protection Fan motor overheating Overcurrent Protection Water Shortage Alarm Over-temperature Protection |
7.2 Safety Mechanism | The heating cannot be activated when the recirculating pump is not running; heating can only begin after the recirculating pump is started. Over-temperature Protection for Enclosure: Once this over-temperature protection is activated, it will cut off the main power supply to the enclosure. |











Adopt