I. Product Introduction:
OrdENThe surge protection module is designed, manufactured, and tested in accordance with international standards IEC61643, national standards GB18802.1, as well as meteorological industry standards QX10.1-2002 and communication industry standards YD/T1235.1-2002. The product is strictly controlled under the ISO9001 quality assurance system.
This product is widely used in power systems for mobile communication base stations, microwave communication stations/offices, telecom equipment rooms, industrial mines, civil aviation, etc., including various power distribution stations, power rooms, distribution cabinets, AC/DC distribution panels, switch boxes, and other important equipment prone to lightning strikes.
◆ Utilizes a pressure-sensitive resistor chip for stable and reliable performance.
◆ Utilizes a plug-and-play structure for easy replacement;
Mechanical thermal release device with high sensitivity.
Modular sealing design, high flow rate, and lower protection level.
Single-phase, capable of being combined into multi-polar for use in various grid configurations.
◆ Equipped with a degradation display window, and can be equipped with a remote遥信output interface.
The shell is made of high flame-retardant materials, ensuring high safety performance.
◆ 35mm track mounting, standard modular design;
Product options include FM alarm function.
◆ A wide variety of product colors and styles available to meet various aesthetic requirements!
◆ Product parameters are for single-module only. For three-phase, please change the model to /4. For single-phase, please change the model to /2.
ThreeTechnical Specifications:

Product Model (Single Module Parameters)
| OD-M40C/4 OD-M40C/4-FM
|
IEC Category/VDE Specification Grade/EN Type
| II/C/T2
|
Working Voltage Un (V)
| 220V
|
Continuous Operating Voltage Uc (V)
| 320V
|
Named discharge current In (kA) 8/20μs
| 20KA
|
Discharge Current Imax (KA) 8/20μs
| 40KA
|
Voltage Protection Level Up (KV)
| ≤1.5
|
Response Time (ns)
| <100
|
Backup yarn (optional)
| 63A
|
Degradation Indicator
| Degradation Indicator Window
|
Work Environment
| -40℃ to +85℃; relative humidity < 95%
|
Product Dimensions
| 18mm
|
Installation wire cross-sectional area
| 2.5mm² - 50mm² Soft Wire/Multifilament Copper Core Wire
|
Ingress Protection Rating, Compliant with IEC 60529/EN 60529
| IP20
|
Insulating Shell Material
| Flame-retardant PBT
|
|
Section 4: Product Installation Instructions:
1. Power must be cut off before installation, and operation with power on is strictly prohibited.
2. It is recommended to connect a fuse or a circuit breaker in series at the front of the lightning protection module.
3. SPD is paralleled installed at the power input end of the building's distribution box or the equipment room. The product features a track-mounted installation, and a Kevin connector type may be used under permissible conditions.
4. Please connect according to the installation diagram provided, where L stands for phase wire, N for neutral wire, and PE for ground wire. Do not connect them incorrectly. After installation, close the automatic circuit breaker switch and check if the operation is normal.
5. During use, the lightning protection module should be regularly inspected and the status of the fault display window checked. If the fault display window shows red or if the remote signal terminal outputs an alarm signal, it indicates a fault in the lightning protection module, and it should be repaired or replaced promptly.
6. Suitable for indoor operation; if installed outdoors, a waterproof housing must be added.
All connections must be secure and reliable electrical connections.
8. Lightning protection grounding should comply with lightning protection regulations, with grounding wires as thick and short as possible, and the grounding resistance should be less than 10Ω.
I. Product Introduction:
OrdENThe surge protection module is designed, manufactured, and tested in accordance with international standards IEC61643, national standards GB18802.1, as well as meteorological industry standards QX10.1-2002 and communication industry standards YD/T1235.1-2002. The product is strictly controlled under the ISO9001 quality assurance system.
This product is widely used in mobile communication base stations, microwave communication offices/stations, telecommunications rooms, industrial mines, and civil aviation power systems, including various power stations, switch rooms, switchboards, AC/DC distribution panels, switch boxes, and other crucial equipment susceptible to lightning strikes.
◆ Utilizes a pressure-sensitive resistor chip for stable and reliable performance.
◆ Utilizes a plug-and-play design for easy replacement.
Mechanical thermal release device with high sensitivity.
◆ Modular sealing design, high flow rate, lower protection level;
Single-phase, capable of being combined into multi-pole for use in various grid configurations.
◆ Equipped with a degradation display window, and can be equipped with a remote遥信output interface.
The housing is made of high flame-retardant material, offering high safety performance.
35mm track mounting, standard modular design.
Product is available with optional FM alarm feature.
◆ A wide variety of colors and styles to meet all aesthetic requirements!
◆ Product parameters are for single-module units. For three-phase, please change the model to /4. For single-phase, please change the model to /2.
ThreeTechnical Specifications:
Product Model (Single Module Parameters)
| OD-M40C/4 OD-M40C/4-FM
|
IEC Category/VDE Specification Grade/EN Type
| II/C/T2
|
Working Voltage Un (V)
| 220V
|
Continuous Operating Voltage Uc (V)
| 320V
|
Named Discharge Current In (KA) 8/20μs
| 20KA
|
Discharge Current Imax (KA) 8/20μs
| 40KA
|
Voltage Protection Level Up (KV)
| ≤1.5
|
Response Time (ns)
| <100
|
Backup yarn (optional)
| 63A
|
Degradation Indicator
| Degradation Indicator Window
|
Work Environment
| -40℃ to +85℃, relative humidity < 95%
|
Product Dimensions
| 18mm
|
Conductor cross-sectional area installation
| 2.5mm2-50mm2 soft wire/multistrand copper-core wire
|
Ingress Protection (IP) rating, conforms to IEC 60529/EN 60529
| IP20
|
Insulating Shell Material
| Flame-retardant PBT
|
|
IV. Product Installation Instructions:
Prior to installation, power must be disconnected, and operation with live power is strictly prohibited.
2. Suggest connecting a fuse or a circuit breaker in series at the front of the lightning protection module.
3. SPD parallel installation at the power input terminal of building distribution boxes or server rooms, with the product featuring a rail-mounted installation. Under permissible conditions, the Kevin connection method may be used.
4. Please connect according to the installation diagram provided: L is the phase wire, N is the neutral wire, and PE is the ground wire. Do not connect them incorrectly. After installation, close the automatic circuit breaker switch and check if the operating status is normal.
5. During use, the lightning protection module should be regularly inspected and the status of the fault display window checked. If the fault display window shows red or the remote signal terminal outputs an alarm signal, it indicates a fault in the lightning protection module, and it should be repaired or replaced promptly.
6. Suitable for indoor operation; if installed outdoors, a waterproof housing must be added.
All connections must be secure and reliable electrical connections.
8. Lightning protection grounding should meet the specifications for lightning protection, with the grounding wire as thick and short as possible, and the grounding resistance should be less than 10Ω.