Duwan Environmental Protection Equipment (Jiangsu) Co., Ltd.VIP

WQ潜水排污泵|AS绞刀泵|AV刮吸泥泵|QJB潜水搅拌机|WL立式污水泵|WQB隔爆型排污泵|LS立式管道泵|自耦装置|LB-05漏水保护器|NS-4综合保护器|INT热保护器|FK2浮球开关|ZQB潜水轴流泵|SQB双曲面搅拌机|QJB-W污泥回流泵|QJB潜水推流器|QXB潜水曝气机|QSB潜水射流曝气机|格栅除污机|刮吸泥机|预制泵站|框式搅拌机|浆式搅拌机|无轴螺旋输送机|砂水分离器|皮带输送机|
Enter Shop

Wall Penetrating Pump Installation Dimensions QJB-W7.5 Wall Penetrating Sludge Pump Price

平台认证
  • Unit Price

    $10000.00/Tai

  • Brand

    Duwan

  • MOQ

    1Tai

Contact
Leave Msg

Platform Service

Supplier Verified



杜安环保设备(江苏)有限公司

VIP   数字营销第3年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    Duwan

  • Unit Price:

    $10000.00 / Tai

  • MOQ:

    MOQ1Tai

  • Total:

    1000Tai

  • Address:

    JiangsuNanjing

  • Delivery:

    3days

  • View More

Description

Wall Penetrating Pump Installation Dimensions

Duwan Environmental QJB-W7.5 Wall Penetrating Sludge Pump Price

DivingRecirculating Pump (Through-the-Wall Pump)

Design, manufacturing, and factory testing technical requirements for recirculating pumps (through-the-wall pumps).

Design Requirements

Item Number

Name

Model and Specifications

Unit

Quantity

Note

Installation Location

1

DivingThroughPump

Q=835m3/h,H=0.5m,N=7.5kW

Tai

4

2 for 2 spare. Equipment set includes a self-coiling four-piece kit, stainless steel guide rod and chain, rod length 5m, chain length 6m; submersible installation, medium sewage chloride ion concentration 500-1200mg/L.

AAO-MBR Pool

2

DivingThroughPump

Q=1666m3/h,H=0.5m,N=7.5kW

Tai

4

2 for 2 spare. Equipment comes with a complete kit of 4 couplings, stainless steel guide rods and chains, with guide rods at 5m and chains at 6m long; submersible installation, medium: wastewater, chloride ions 500-1200mg/L.

AAO-MBR Tank

3

DivingIntegratedPump

Q=2084m3/h,1m,N=11kW

Tai

6

4 in use, 2 in reserve. Equipment set includes a self-coupling kit of four pieces, with stainless steel rods and chains; rod length 5m, chain length 6m; submersible installation, medium: wastewater, chloride ion concentration 500-1200mg/L.

AAO-MBR Tank

Duwan Environmental Wall Penetrating Pump, Sludge Recirculation PumpTechnical Performance and Structure

1) General Requirements

each unitRecirculationThe pump should be capable of continuous operation, intermittent operation, and resuming operation after a long-term shutdown under full immersion conditions.

b. The pump should be able to withstand reversal caused by backflow without causing any harm to the pump.

c. The pump unit, within the designed scope of supply, should operate without vibration, cavitation, and run smoothly. The pump's rotor components should undergo dynamic and static balance tests.

d. The pump housing must have sufficient thickness to bear all loads, including the hydrostatic test pressure and continuous working pressure.

e. The impeller and pump shaft are keyed and secured at the shaft end, with sealing applied. A locking device must be used on the impeller and shaft to prevent loosening, whether the impeller and shaft are rotating clockwise or occasionally reversing.

f. The impeller shall undergo dynamic and static balancing tests.

g. The shaft of the pump and motor should be a continuous, uninterrupted shaft, with the pump shaft being an extension of the motor shaft. Coupling is not acceptable.

h. The upper bearing should be a single row ball bearing. The lower bearing should be a double row radial thrust bearing, used to bear radial forces and axial thrust. The bearings of itsPlease provide the Chinese content that needs to be translated into American English.Small work life100,000 hours.

i. The lower bearing should be equipped with a thermal sensor to monitor bearing temperature. The sensor must be in direct contact with the thrust bearing housing. If the temperature rises, the sensor will trigger an alarm and stop the pump.

Each pump should be equipped with a double independent mechanical seal system, with the lower seal separated from the impeller hub. The mechanical seal must operate within the oil cavity, which lubricates the overlapping seal surfaces at a stable flow rate. The mechanical seal should operate normally in both clockwise and counterclockwise directions without damaging or losing any seal components, and without requiring maintenance or adjustment.

k. The mixed liquid recirculation pump is mainly composed of a impeller, submersible motor, self-coupling system, non-return valve at the outlet, short pipe, guide rod, and lifting device, etc. Its design should ensure the pump's convenient and reliable operation. The pump is mounted on the guide rod for easy lowering. The self-coupling system ensures a quick, convenient, and reliable connection to the pool wall water pipes.

The impeller of the mixed liquid recirculation pump is a self-cleaning propeller blade impeller. Its structure should ensureMaximizeFlow rate is smooth without clogging or slagging; the blade angle should be selected according to the operating conditions.NormalValue.

All mixed liquid recirculation pumps are equipped withImportedNSK Bearings

Export Swing Check Valve (inclusive of outlet short pipe)

a. The door knock valve body sealing surface should be provided with approximately 10°The inclination is sealed with a rubber soft seal, connected to the short pipe flange of the mixed liquid recirculation pump outlet via a flange.

b. The gate valve is designed with a double-hinged structure, with no casting defects allowed on the valve body and valve plate. Surface corrosion protection coating is applied.

c. The resistance of the butterfly valve during export does not affect the normal start-up and operation of the mixing liquid return pump, and it is required that the butterfly valve be leak-proof under the given reverse water head pressure.

2) Electric Motor

The motor is an induction squirrel-cage motor.

Motors are designed specifically for submersible pumps and capable of continuously pumping at temperatures of40°Medium C. To monitor the temperature of each phase winding, a thermal switch should be installed in the stator winding coils. The thermal switch should be connected to the external motor overload protection and connected to the control cabinet.

The motor allows for voltage fluctuations of10%, motor design at 40%°Operate under C environment, and the average temperature rise of the stator winding does not exceed 85.°C, a performance sheet should be provided that displays torque, current, power factor, input/output power, and efficiency. This performance sheet should also include data on startup and no-load characteristics.

Please provide the signal specifications for each protective sensor of the motor to ensure signal transmission.MCC。

The motor's stator winding must be installed with an over-temperature sensor.

Install leakage prevention sensors to prevent liquid from entering the stator windings.

The water detection device should be installed in the motor's cable junction box.

3) Cable Entry Seal

The cable entry seal design should be capable of eliminating a certain amount of torque to form a waterproof diving seal. Measures should be taken in the cable joint section to prevent air exchange between the internal and external air of the cable due to temperature differences. The cable entry seal should ensure ease of cable replacement; it cannot be sealed with epoxy, silicone, or any other secondary sealing system.

Cable joint sections should implement measures to prevent air exchange between the cable's inner and outer layers due to temperature differences.

Cables should be protected reliably and securely fastened to prevent damage from water flow impact.

 


Jiangsu Du'an Environmental Protection Sludge Recirculation PumpKey components materials

Blade impeller

AISI 304

Axle

AISI 304

Guide ring with coupling claw and bracket

AISI 304

Mechanical Seal

Tungsten Carbide or Silicon Carbide

ChainWire Rope

AISI 304

Guides, brackets

AISI 304

Mobile hoists and lifting equipment

AISI 304

All connected accessoriesAnchoring Bolt

AISI304

Wall penetrating pipes, export short tubes, and flanges

AISI 304

Pilot Valve Body

AISI 304


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $10000.00 / Tai
Sales None
Delivery JiangsuNanjing3dayswithin
Stock 1000TaiMOQ1Tai
Brand Duwan
Voltage 380V
Material 304 Stainless Steel
Impeller diameter 620mm
Expiry Long Valid
Update 2024-11-19 10:28
Gallery

Duwan Environmental Protection Equipment (Jiangsu) Co., Ltd.Published byWall Penetrating Pump Installation Dimensions QJB-W7.5 Wall Penetrating Sludge Pump PriceGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top