KVVP4*1.5 Shielded Power Cable Price
Standard: Company Standard Q/TX001-2006; This standard applies to flame-retardant control cables with copper-core polyvinyl chloride sheath for use in coal mines.
Cable Model, Name, Specifications, and Application
Model
Name, Specifications, Usage
MKVV
Copper-core polyethylene insulated, PVC jacketed, flame-retardant mining control cables
(2-14)*(4-6)
(2-61)*(0.75-2.5)
Laid in indoor settings, within cables, pipelines, and other fixed installations
MKVV22
Copper-core polyethylene insulated PVC sheathed steel tape armored flame-retardant mine control cable
(7-61)*(0.75-1.5)
(4-14)*(4-6)
Laid indoors, within cables, pipelines, or directly buried, capable of withstanding significant mechanical external forces for fixed installations.
MKVV32
Copper-core polyethylene insulated PVC sheathed steel wire armored flame-retardant mining control cable
(2-61)*(0.75-2.5)
(4-14)*(4-6)
Laid indoors, within cables, pipelines, buried directly, or suspended, capable of withstanding significant tensile forces for fixed installations.
MKVVP22
Copper-core polyethylene insulated polyvinyl chloride sheathed braided shielding steel tape clad flame-retardant control cable for coal mines
(4-14)*(4-6)
(4-61)*2.5mm2
Laid in high-magnetic field rooms, cables, pipelines, direct burial, and suspended installations, capable of withstanding significant tensile forces.
MKVVRP
Copper-core Polyethylene Insulated Polyvinyl Chloride Sheathed Braided屏蔽 Flame-retardant Control Flexible Cable for Coal Mines
(4-61)*(0.5-2.5)
(4-37)*(1.5-2.5)
Laid in fixed locations such as rooms with strong magnetic fields, cables, pipelines, etc.
KVVP4*1.5 Shielded Power Cable Price
MKVV cables, MKVVP cables, MKVVP2 cables, MKVV22 cables, MKVV32 cables, MKVVR cables, MKVVRP cables, MKVVP22 cables, and other specifications of coal mine flame-retardant control cables, ***with conductor counts of 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37, 44, 48, 52, and 61 cores.
MKVV(2-14)*(4-6)mm2 ,(2-10)*10mm2 (2-61)*(0.75-2.5)mm2 MKVV22(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2 MKVVP(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2 MKVVP22(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2
Rated Voltage: 450/750V
The length of the cable conductor is permitted to operate at a temperature of 70 degrees Celsius.
The laying temperature of the cable should not be below 0 degrees Celsius, with an allowable bending radius of ***.
Unarmored cables should not be less than 6 times the cable's outer diameter.
Cables with armored or copper braid shielding should have a diameter not less than 12 times the cable's outer diameter.
Flexible cables with a shielding structure should not be less than 6 times the cable's outer diameter.
MT386-1995 "Test Methods and Evaluation Rules for Flame Retardant Properties of Flame Retardant Cables Used in Coal Mines" and Q/TX 001-2006 "Plastic Insulated Control Cables for Coal Mines"
KVVP 4*1.5 Shielded Power Cable Price