The Gree Full-liquid Water-Cooled Screw Chiller adopts the new-generation environmentally friendly refrigerant R134a, ensuring stable and reliable operation, as well as energy conservation and environmental protection. The cooling capacity range under nominal conditions is: 182-1560KW, and it is widely applicable to various office buildings, schools, and shopping malls, as well as for temperature reduction in production processes.
|
| One. Gree Central Air Conditioning – Product Features |
| 1. Gree Central Air Conditioning - High Energy Efficiency | |
● Gree Central Air Conditioner - Full Liquid Evaporation Technology The refrigerant distribution in the evaporator is more uniform, optimizing the temperature field for higher heat exchange efficiency; the full liquid evaporator significantly increases the evaporation temperature of the unit, enhancing its heat exchange efficiency. Paired with a high-performance, high-reliability screw compressor, it greatly boosts the refrigeration capacity and energy efficiency of the unit.
Automatically calculates the energy efficiency ratio, rapidly adjusts the actual value as needed, and outputs accordingly, further optimizing the control logic. | |
● Gree Central Air Conditioning - Higher efficiency in multi-machine parallel operation and part load Due to the majority of operating time being outside of the designed conditions, attention should be paid when selecting a chilled water unit. |
● Gree Central Air Conditioning - Capacity Adjustment and Unit Load Matching Available for adjustable capacity, stepless or stepped, as per customer requirements. The compressor starts at low load position and can be infinitely adjusted for cooling capacity. Continuous sliding gate regulation for forced gas input, perfectly matching the actual load. |
| 2. Gree Central Air Conditioning - High Reliability |
◆ Reliable Return Oil System Specifically designed for flooded-type chillers, it features low-oil level protection control, completely eliminating the possibility of compressor damage due to insufficient oil.
During online screw unit inspections, we utilize an industry-standard online inspection system (developed by the Fertilizer Machinery Research Institute, featuring a barcode management system and a super-large online inspection system with computerized automatic detection and judgment). |
3. Gree Central Air Conditioning - Eco-friendly This series of full-liquid water-cooled screw chiller units utilizes the environmentally friendly refrigerant R134A, which is widely recognized in the industry as a green refrigerant, contributing to comfortable and eco-friendly living. |
| Section 2: Gree Central Air Conditioning - Control System |
| 1. Color Image Display Control Center(彩色 touch screen is optional) |
● Gree Central Air Conditioning - Advanced Control Platform
●Advanced control algorithms
|
● Gree Central Air Conditioning - Gree Commercial Large Unit Monitoring Center One, receive and confirm debugging data for large-scale units (centrifugal machines, screw machines, etc.), ensuring the units are delivered to the customer in a reliable condition.
The central control center can intelligently control chilled water systems, electric butterfly valves for chilled water systems, cooling water pumps, chilled water pumps, cooling tower electric butterfly valves, supply/return water temperatures of the main chilled water pipeline, expansion tank liquid levels, pressure difference bypass valves, and more. It automatically adjusts the operation of pumps, cooling towers, and chilled water systems based on the load changes of terminal equipment, aiming to keep the entire machine room system running in an energy-saving state, ultimately achieving an unmanned machine room.
● Gree Central Air Conditioning - Remote Control Center Gree's screw compressor unit remote monitoring/BMS interface kit, developed using the internationally popular Modbus communication protocol and the universally applicable Internet communication interface standards, allows our products to seamlessly integrate with customers' existing building systems, enabling an intelligent monitoring system. Additionally, for buildings without a building management system, we offer our independently developed monitoring software, facilitating intelligent management of the customers' air conditioning systems.
The full-Chinese LCD touch screen with a large display offers a more user-friendly human-machine interface, featuring various display methods such as text, images, tables, and curves. It can record and display the operating status of the unit, sensor statuses, valve statuses, and operating parameters from multiple angles, enabling effective monitoring of the unit.
Event logs for unit operation, curve record information. Can be downloaded to a USB flash drive via the touch screen USB port, convenient for owners to check the air conditioner's operating status and perform unit maintenance. |
| Section 3: Gree Central Air Conditioning - Product Installation |
1. Installation Foundation & Environment Installation Environment ◆ The crew should avoid approaching fire sources and flammable materials. When installed alongside heat sources such as boilers, sufficient attention should be paid to the effects of heat radiation. Gree Central Air Conditioning – Installation Foundation The installation foundation for the unit must be made of concrete or steel structure, capable of supporting the operating weight of the machine, and the upper surface must be level. A drainage channel should be reserved for the installation foundation of the unit.
|
Engineered Unit Name | A(mm) | B(mm) | D(mm) | M(mm) | K(mm) |
LSBLG180H/Nb | 3160 | 1350 | 1150 | 2630 | 740 |
LSBLG210H/Nb | 3160 | 1350 | 1150 | 2630 | 740 |
LSBLG240H/Nb | 3160 | 1350 | 1150 | 2630 | 740 |
LSBLG300H/Nb | 3160 | 1600 | 1400 | 2630 | 920 |
LSBLG340H/Nb | 3160 | 1600 | 1400 | 2630 | 920 |
LSBLG380H/Nb | 3160 | 1600 | 1400 | 2630 | 920 |
LSBLG450H/Nb | 3160 | 1720 | 1520 | 2630 | 1100 |
LSBLG500H/Nb | 3160 | 1720 | 1520 | 2630 | 1100 |
LSBLG580H/Nb | 3160 | 1720 | 1520 | 2630 | 1100 |
LSBLG640H/Nb | 3160 | 1720 | 1520 | 2630 | 1100 |
LSBLG680H/Nb | 3400 | 1900 | 1700 | 2830 | 1210 |
LSBLG760H/Nb | 3400 | 1900 | 1700 | 2830 | 1210 |
LSBLG880H/Nb | 3900 | 2000 | 1900 | 3330 | 1420 |
LSBLG1000H/Nb | 3900 | 2000 | 1900 | 3330 | 1420 |
LSBLG1160H/Nb | 3900 | 2000 | 1900 | 3330 | 1420 |
LSBLG1280H/Nb | 3900 | 2000 | 1900 | 3330 | 1420 |
LSBLG1400H/Nb | 4400 | 2100 | 1900 | 3830 | 1420 |
LSBLG1500H/Nb | 4400 | 2100 | 1900 | 3830 | 1420 |
| 2. Gree Central Air Conditioning - External Dimensions and Connection Sizes |
Mark | Name | Mark | Name |
1 | Electrical Control Box | 5 | Cooling water inlet |
2 | Screw compressor | 6 | Cooling water outlet |
3 | Evaporator | 7 | Chilled water inlet |
4 | Condenser | 8 | Chilled water outlet |
3. Gree Central Air Conditioning - Installation & Maintenance Space
Leave space for equipment installation and operation. (2) The installation location of the unit should ensure that the machine is protected from direct sunlight and rain; it should be as free as possible from the effects of fire, flammable materials, corrosive gases, or exhaust fumes; ventilation space should be provided; appropriate measures should be taken to minimize noise and vibration as much as possible. |
Engineered Unit Name | A | B | C | D | H |
LSBLG180H/Nb | 600 | 600 | 2600 | 1000 | 500 |
LSBLG210H/Nb | 600 | 600 | 2600 | 1000 | 500 |
LSBLG240H/Nb | 600 | 600 | 2600 | 1000 | 500 |
LSBLG300H/Nb | 600 | 600 | 2600 | 1000 | 500 |
LSBLG340H/Nb | 600 | 600 | 2600 | 1000 | 500 |
LSBLG380H/Nb | 600 | 600 | 2600 | 1000 | 500 |
LSBLG450H/Nb | 600 | 600 | 2600 | 1000 | 500 |
LSBLG500H/Nb | 600 | 600 | 2600 | 1000 | 500 |
LSBLG580H/Nb | 600 | 600 | 2600 | 1000 | 500 |
LSBLG640H/Nb | 600 | 600 | 2600 | 1000 | 500 |
LSBLG680H/Nb | 600 | 600 | 3000 | 1000 | 500 |
LSBLG760H/Nb | 600 | 600 | 3000 | 1000 | 500 |
LSBLG880H/Nb | 600 | 600 | 3000 | 1000 | 500 |
LSBLG1000H/Nb | 600 | 600 | 3500 | 1000 | 500 |
LSBLG1160H/Nb | 600 | 600 | 3500 | 1000 | 500 |
LSBLG1280H/Nb | 600 | 600 | 4000 | 1000 | 500 |
LSBLG1400H/Nb | 600 | 600 | 4000 | 1000 | 500 |
LSBLG1500H/Nb | 600 | 600 | 4000 | 1000 | 500 |
| 4. Gree Central Air Conditioning - Unit and External Field Wiring Instructions (1) General Principles
|