JCH-15KW-AC400V-RLC RLC Load
I. Product Overview
JCH-15KW-AC400V/RLCBuilt-in resistive and capacitive loadsCan simulate various resistancesRCapacitiveLSentimentalCCommunication load, simulate various operating environments for inverters, can detect the actual output power and load-bearing capacity of inverters, can detect the resonant point of PV inverters, power input uses segmented combination control, can arbitrarily combine various power inputs; RLCProgrammable AC Load is mainly used for inverters,UPSApplications for AC power detection of generators and power units.
II. Reference Standards and Regulations
1、QC/T 895-2011 Conductive on-board charger for electric vehicles
2、YD/T1095-2008 Uninterruptible Power Supply for Communication(UPS);
3、GB 19212.1-2008 Safety of power supplies, reactors, and similar products: General requirements.
4、GB/T 14048.1-2000 General provisions for low-voltage switchgear and control gear
5、GB/T 13032-2010 Marine diesel generator set
6、GB 5226.1-2002 Mechanical Safety Mechanical and electrical equipment: General technical specifications.
7、GJB 235-87 General technical specifications for industrial and medium-frequency mobile loads
8、NB/T 42053-2015 Isolation Effect Test Device Technical Conditions
9. NB/T 32010-2013 Technical Code for Inverter Anti-Islanding Detection Technology of Photovoltaic Power Stations
III. Technical Specifications
Equipment Technical Specifications | |
Model | JCH-15KW-AC400V/RLC |
Load Type | Single-phase power factor adjustable CLoaded+RLoaded+LLoaded |
Rated Input Voltage | 230VAC |
NamedRRated Power | 5050WSingle-phase) |
Please provide the Chinese content to be translated.CRated Power | 5050VA |
Please provide the Chinese content to be translated.LRated Power | 5050VA |
Load Type | R、L、CSingle shipment |
Power Factor Adjustment | 0.7~1Adjustable |
Loading method | Multi-tiered |
Gear position | 8FileR+8FileLLoaded+8FileCLoaded |
RCarrying capacity | 50W/100W/200W/200W/500W/1KW/1KW/2KW |
LCarrying capacity | 50VAR/100VAR/200VAR/200VAR/500VAR/1KVAR/1KVAR/2KVAR |
CLoaded position | 50VAR/100VAR/200VAR/200VAR/500VAR/1KVAR/1KVAR/2KVAR |
Load Accuracy | ±5% |
RPower rating adjustment range | 0~5050W |
Control Method | Circuit Breaker |
Total Instant Loading | Available |
Total Load Method | Ship-shaped switch + contactor |
Load Stress Control | N/A |
Input Display | LEDDisplay, Voltage, Current, Active Power/PF |
Protection Method | Over-temperature automatic shutdown, power supply interruption automatic shutdown |
Alarm Method | N/A |
Load Input | Anderson connector |
Power Supply | AC: 220V/50Hz |
Power Input Method | 10APlug |
Operation surface | Top |
Resistor Type | Stainless Steel Power Resistors |
Insulation Grade | FGrade |
Protection Level | IP20 |
Fan Noise | 75Decibels |
Cooling Method | Air-cooled |
Work Method | Continuous operation72HThe above |
Protection Features | Overheating |
External Dimensions | 600mm*800mm*800mm(For reference; actual may vary) |
Applicable Environmental Temperature | -20℃ ~ 50℃ |
Mode of Transport | caster mobility |
Relative Humidity Applicable | ≤95% |
Altitude | ≤4000Rice |