38DL PLUS Ultrasonic Thickness Gauge

38DL PLUSThis is a high-end ultrasonic thickness gauge. The instrument can detect internal corrosion in components using dual crystal probes. Its features include THRU-COAT® (penetrating coating) and echo-to-echo. It also offers very reliable thickness measurements for thin materials, extremely thick materials, and multi-layer materials using single crystal probes.
38DL PLUSUltrasonic Thickness Gauge
High performance, easy to operate, sturdy and durable, reliable results
The 38DL PLUS thickness gauge represents a new era in ultrasonic thickness measurement technology. This portable thickness gauge is suitable for nearly all ultrasonic thickness applications and is fully compatible with all dual-element and single-element probes. The feature-rich 38DL PLUS gauge is applicable for various uses, including measuring wall thinning of piping components with internal wall corrosion using dual-element probes, as well as for extremely reliable wall thickness measurements on thin-walled or multi-layer materials using single-element probes.
The standard configuration of the 38DL PLUS comes equipped with a range of powerful and user-friendly measurement features, along with some software options for specific applications. Its sealed housing design meets IP67 rating requirements, making it resistant to extremely humid or dusty harsh environmental conditions. The color transreflective VGA display ensures excellent visibility on the thickness gauge's screen, whether in bright sunlight or complete darkness. The keypad is both simple and ergonomic, allowing operators to easily access all functions with either hand.

Key Features
Compatible with both dual crystal and single crystal probes.
Wide thickness range: 0.08mm to 635mm, depending on the material and selected probe.
Thickening measurement through corrosion testing with a dual crystal probe.
Penetration coating and echo-to-echo measurement function for measuring materials with coatings and lacquer on the surface.
Internal Oxide Layer/Deposition Software Option.
For all probes, the standard resolution is 0.01 millimeters.
Single crystal probe with a frequency range of 2.25 MHz to 30 MHz, featuring high-resolution software options for thickness measurement with a resolution of 0.001 mm.
Multi-layer software options allow for simultaneous measurement of up to 4 different layers.
High-penetration software options for measuring materials with high attenuation, such as fiberglass, rubber, and thick castings.
Thickness, sound velocity, and transit time measurement.
Differential Mode and Reduction Rate Mode.
Time-based B scan mode; each scan yields 10,000 readable counts.
Olympus high dynamic range technology with digital filter.
V-tuning creation feature for custom V-tuning compensation.
Design complies with EN15317 standard.
What sets this thickness gauge apart from other thickness gauges?
The 38DL PLUS thickness gauge is designed to meet stringent application requirements and operates reliably in harsh field and production site conditions. It can perform normal detection tasks regardless of the humidity, dust, coldness, heat, brightness, or darkness of the detection site. If you need a shockproof, fall-proof, sturdy thickness gauge, the 38DL PLUS, which meets IP67 rating standards and comes with a rubber protective sleeve, is the instrument you're looking for.
Ability to withstand harsh environments
Compact, weighing only 0.814 kg.
Robust and durable, designed to meet IP67 standards.
Explosive Atmosphere: Operates safely in explosive atmosphere conditions defined under Section I, Division 2, Group D of Article 500 in the National Fire Protection Association (NFPA 70) Standard, having passed the testing as per the MIL-STD-810F Method 511.4 Procedure I.
Impact Resistance Test: Passed the testing as specified in MIL-STD-810F Method 516.5 Procedure I, with 6 cycles per axis, 15 g, and 11 msec half-sine wave.
Vibration Resistance Test: Passed the testing according to MIL-STD-810F Method 514.5 Procedure I Appendix C Figure 6; General Exposure: 1 hour per axis.
Wide operating temperature range.
Rubber protective sleeve with stand.
Color-through reverse VGA display with indoor and outdoor color settings, maintaining the same clarity.

User-friendly design philosophy

Outdoor Display Setup, A Scanning ModeIndoor Display Settings, B Scan Mode
A simple keypad designed for operation with either the right or left hand, single-handedly.
Easily accessible, straightforward interface with direct access to all features.
Built-in and external MicroSD storage cards.
USB and RS-232 communication ports.
A alphanumeric data logger that can store 475,000 thickness readings or 20,000 waveforms.
VGA output compatible with computers or monitors.
Default or customizable dual crystal probe setup.
Default or custom single crystal probe settings.
Password protection feature can lock the instrument's functions.
Data recorder and PC interface

38DL PLUSThe thickness gauge comes equipped with a fully featured built-in bidirectional alphanumeric data recorder, allowing for easy collection and transmission of thickness readings and waveform data.
Built-in storage capacity for 475,000 thickness readings or 20,000 waveforms with thickness readings.
32-character file name.
20-character ID# (TML#) encoding.
9 file formats: Incremental, Sequential, Sequential with Custom Points, 2D Grid, 2D Grid with Custom Points, 3D Grid, 3D Custom, Boiler, and Manual.
Each ID# (TML) can store up to 4 annotations.
Notes can be stored on an ID# code or across a series of ID# codes.
Built-in and external MicroSD storage cards.
You can copy files between the built-in and external MicroSD storage cards.
Standard USB and RS-232 communication.
Single and double crystal probe setup for bidirectional transmission.
Aboard Statistics Report
Aboard DB lattice view with 3 programmable colors.
The GageView interface program communicates with the 38DL PLUS thickness gauge via USB or RS-232 ports, enabling data reading from a MicroSD storage card and also writing information to it.
Files can be directly exported to a MicroSD storage card in CSV (Comma Separated Values) format compatible with Excel.
GageView™
The GageView interface program based on Windows is used for collecting, creating, printing, and managing data from the 38DL PLUS thickness gauge.
Create datasets and measurement summaries.
Edit saved data.
Display data sets and measurement summary files, which include thickness readings, micrometer settings, and probe settings.
Download thickness measurement summary from the thickness gauge, or upload the summary to the thickness gauge.
Export measurement summaries to spreadsheets and other programs.
Collect captured screens.
Print reports on thickness, set tables, statistics, and color grids.
Upgrade the operation software.
Download and upload single and double crystal probe setup files.
B Scan Review

Aboard DB lattice view with 3 programmable colors.
Standard Configuration
38DL PLUSDigital ultrasonic thickness gauge, AC powered or battery-operated, 50 Hz to 60 Hz.
Standard Double Crystal Probe Set Box
Charger/AC Adapter (100 VAC, 115 VAC, 230 VAC)
Built-in data recorder
GageView Interface Program
Test blocks and coupling agents
USB Cable
Rubber protective case with stand and neck strap
User Manual
Two-year limited warranty
Measurement Features: Penetrating Coating, Penetrating Paint Layer Echo to Echo, EMAT Compatible, Min/Value Mode, Two Alarm Modes, Differential Mode, B-Scan, Automatic Application Call, Temperature Compensation, Average/Min Value Mode
Primary Technical Specifications
Measurement | |
Dual Crystal Probe Measurement Mode | The precise time interval from the激励 pulse to the first echo. |
Penetrating Coating Measurement Mode | Measure the actual thickness and coating thickness of metal using a single bottom surface echo (with D7906-SM and D7908 probes). |
Penetrate paint layer to echo measurement mode | The time interval between two consecutive bottom surface echoes, excluding the thickness of the paint or coating layer. |
Monocrystalline probe measurement mode | Mode 1: Time interval between the激励 pulse and the first bottom surface echo. Mode 2: Time interval between the delayed line echo and the first bottom surface echo (using a delayed line or water immersion probe). Mode 3: Time interval between the adjacent bottom surface echoes following the first surface echo, after the激励 pulse, using delay-line or water-immersed probes. |
Oxide Layer Pattern: | Optional. |
Multi-layered Model: | Optional. |
Thickness range | 0.080Millimeters ~ 635.00 mm, depending on material, probe surface conditions, temperature, and selected configuration. |
Material Sound Velocity Range | 0.508 mm/μs~13.998 mm/μs |
Resolution (Optional) | Low Resolution: 0.1 mm Standard Resolution: 0.01 millimeter High Resolution (optional): 0.001 mm |
Probe Frequency Range | Standard: 2.0 MHz to 30 MHz (-3 dB) |
High Penetration (Optional): | 0.50 MHz~30 MHz(-3 dB) |
General specifications | |
Operating Temperature Range | -10°C~50°C |
Keypad area | Sealed keyboard with color-coded function differentiation, featuring tactile and audio feedback. |
Chassis | Impact-resistant, waterproof housing with sealed gaskets; interfaces on the housing are sealed. Design complies with IP67 standard. |
Dimensions (Width x Height x Depth) | Overall Dimensions: 125mm x 211mm x 46mm |
Weight | 0.814pounds |
Power Supply | AC/DCAdapter, 24V; lithium-ion battery, 23.760Wh; or 4 AA auxiliary batteries. |
Lithium-ion Battery Runtime | Work Hours: Minimum 12.6 hours, typically 14 hours, maximum 14.7 hours. Fast Charging: 2 to 3 hours. |
Standard | Design meets EN15317 standard. |
Display | |
Color-Through Reverse VGA Display | LCD display, screen size: 56.16mm x 74.88mm |
Detector | Full Wave, RF Wave, Positive Half-Wave, Negative Half-Wave |
Input/Output | |
USB | 1.0From the interface. |
RS-232 | Yes. |
Memory Card | Capacity: 2GB External MicroSD Storage Card. |
Video Output | VGAOutput Standards. |
Built-in data recorder | |
Data Logger | 38DL PLUSIdentify, store, playback, clear, and transmit thickness readings, waveform images, and instrument configuration information via standard RS-232 serial port or USB port. |
Capacity | 475000A thickness measurement reading, or 20,000 waveforms with thickness values. |
Filename, ID Code, and Comments | 3220-character filename, 20-character alphanumeric code, with four comments per position. |
File Structure | 9A standard or custom file structure for a specific application. |
Report | The airborne report summarizes data statistics, minimum/valued with location information, minimum review, file comparison, and alarm reports. |