Key Features
u Output up to6Phase voltage6AC current, can be freely combined to achieve conventional4Phase Voltage3AC Current Type6Phase voltage type6AC Current Type, as well as12Similar output mode.
u High-performance embedded industrial control computers104" large screen high-resolution color TFT LCD display, offering rich and intuitive information such as the current status of the equipment, next-step work prompts, and various help messages.
u The output end utilizes high-fidelity, high-reliability modular linear amplifiers, not switching amplifiers. It does not cause high and medium-frequency interference at the test site and ensures smooth waveforms and excellent precision throughout the entire current range from high to low.
u OutputPartially adoptedDSPControl, fast computational speed, strong real-time digital signal processing capability, wide transmission bandwidth, high-resolution controlD/AHigh precision and low distortion in output waveforms. Utilizes advanced technologies and precision components, with a professional structural design, resulting in a compact, lightweight, and fully functional device that is easy to carry and operate immediately upon startup, making mobile testing very convenient.
u Capable of performing various high-automation complex verification tasks, it conveniently tests and scans various protective setpoints, conducts fault playback, stores test data in real-time, displays vector graphs, and prints reports online.
u Established with an independent line110V And220VDirect current power output, convenient for on-site inspection.
u New GenerationTest InstrumentEstablishAvailable10Road access and8Road opened for convenient conducting of backup and self-testing experiments. Input terminal is an empty contact.0~250VPotential contact compatible, capable of intelligent automatic recognition.
u Offer a variety of automated testing software modules andGPS Synchronized Trigger Test (optional).
u Can handle various complex verification tasks, easily test and scan various protective setpoints, and perform fault playback. Capable of real-time storage of test data, displaying vector graphs, printing reports, etc.;
u The heat dissipation structure is designed rationally, with reliable and comprehensive hardware protection measures. It features a soft power-on start, software self-diagnosis of faults, and output locking functions.
Rated Parameters
— AC Current Output
6AC CurrentOutputEach Phase Output (RMS) 0~30A
Output Precision ≤0.5A ±2mA
>0.5A 0.2%
3AC CurrentOutputEach Phase Output (RMS) 0~30A
6Parallel Current Output (RMS) 0~180A
Allowable working value (RMS) for AC current over a long period 10A
AC Current * Max Output Power 400VA
6In parallel current*Allowed working hours during high output10s
Frequency Range (Fundamental Wave) 0~1000Hz
Harmonic Order 1~20 Next
— Direct Current (DC) Current Output
Current Output 0~±10A / Each phase,0~20A / Combined effect Output Precision 0.5Grade
*High output load voltage 20V
— AC Output Voltage
Phase Voltage Output (RMS) 0~120V Output Precision 0.2Grade
Line Voltage Output (RMS) 0~210V
*Please provide the Chinese content you would like translated into American English.VoltageOutput Value 0~240V
Phase Voltage / Line Voltage Output Power 80VA / 100VA
Frequency Range (Fundamental Wave) 0~1000Hz
Harmonic Order 1~20Next
— Direct current (DC) voltage output
Phase voltage output amplitude 0~±160V Output Precision 0.5Grade
Line Voltage Output Amplitude 0~320V
Phase Voltage/ Line Voltage Output Power 70VA / 140VA
— Switch quantity
10Road switch quantity input
No contact point 1~20mA,24V
Potential Contact Interface “0”:0 ~ +6V; “1”:+11 V ~ +250 V
8Switching quantity output DC:220 V/0.2 A;AC:220 V/0.5 A
— Time Measurement Range
0.1ms ~ 9999s , MeasurementAccuracy <0.1mS
— Volume Weight
360*425*215mm ,19.8kg