Beijing Lanxing Hualing Decoration Engineering Co., LtdVIP

Enter Shop

Garage glass canopy

平台认证
  • Unit Price

    Negotiable

  • Brand

    Lanxing Hualing

  • MOQ

Platform Service

Supplier Verified



Beijing Lanxing Hualing Decoration Engineering Co., Ltd

游客未注册
资料未认证
保证金未缴纳
该发布人未在本站注册,信息真实性无法保证,请谨慎选择,建议优先选择VIP会员
Category
  • No Category

Product Details

Specs

Gallery

  • Brand:

    Lanxing Hualing

  • Unit Price:

    Negotiable

  • MOQ:

  • Total:

    0

  • Address:

    Beijing

  • Delivery:

    3days

  • View More

Description

Curved underground garage canopy





Underground garage steel structure glass canopy


Public buildings should determine the heat transfer coefficient and shading coefficient of the transparent part of the glass curtain wall based on the window to wall ratio and shape coefficient, while public buildings should determine the heat transfer coefficient and shading coefficient of the transparent part of the glass curtain wall based on the window to wall ratio and shape coefficient. So, what are the basic and performance parameters of glass curtain wall construction? Learn more about the following content!

1、 Basic parameters

The horizontal expansion modulus of the building curtain wall is increased from 900mm to 6000mm, and the vertical expansion modulus is increased from 2700mm to 6000mm. If the project needs to cross the above dimensions, it can be studied separately with the manufacturer.

2、 Performance parameters

1. Wind resistance performance: The standard value of wind load should not be less than 1.0kPa. The deflection limit of glass ribs should be taken as L/200 of their calculated span. Technical performance of high-rise glass curtain wall insulated glass and laminated insulated glass

2. Water tightness performance: The water tightness of fixed parts in areas affected by tropical storms and typhoons should not be less than 1000Pa, the water tightness of fixed parts in other areas should not be less than 700Pa, and the water tightness of open parts should not be less than 150Pa.

3. Airtightness performance: It should not be lower than level 3, and the air permeability at the fixed joint should be 0.05 q ≤ 2.5m3/m · h.

4. Thermal insulation performance: The heat transfer coefficient and shading coefficient of the transparent part of the glass curtain wall in public buildings should be determined based on the window to wall ratio and shape coefficient, in accordance with the provisions of GB50189-2005 "Energy saving Design Standard for Public Buildings".

The above is a complete introduction to the basic and performance parameters of glass curtain wall construction. We hope this article can be helpful to everyone. If you want to learn more related information, please continue to follow us.


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery Beijing3dayswithin
Brand Lanxing Hualing
Scope of Services extensive
service quality premium
price reasonable
Expiry Long Valid
Update 2022-09-24 17:24
Gallery

Beijing Lanxing Hualing Decoration Engineering Co., LtdPublished byGarage glass canopyGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top