价 格¥6600.00
最小起订0 ton库存0 ton
Environmental-friendly chimney to
¥6500.00/ton
Fire Training Tower
¥6500.00/ton
Dual-window Training Tower
¥6560.00/ton
Multi-layer Double Window Trainin
¥6600.00/ton
Single-tube lightning rod tower
¥6520.00/ton
Power steel pole
¥6450.00/ton
Step-up substation structure
¥6520.00/ton
Bionic Tree Tower
¥6500.00/ton
Bionic Tower
¥6580.00/ton
Bionic Signal Tower
¥6560.00/ton


Basic parameters requirements for fire training tower:
One, the training tower should be located near the end of the training ground.
The training tower should have at least four floors, and in cities with a high number of high-rise buildings, the number of floors can be appropriately increased.
Section 3: Each floor of the training tower's facade has at least two windows, with a width of the wall between windows at 1.0 meter.
Four, the size of the training tower window is 1.2m x 1.8m, the distance from the window to the tower edge must not be less than 0.65m, the window sill width is 0.4m (protruding from the tower wall by 5cm), the height of each window sill from the floor of that level is 0.8m, the height of each level is 3.5m, and an inner staircase with a clear width of not less than 0.7m should be provided.
5. Inside each level of the training tower, a platform of not less than 1.5 meters in width should be provided. The top level should have a floor. 6. It is advisable to install an outdoor fire escape ladder on the training tower. The ladder should extend to the top of the tower and ideally start at a height of 3 meters from the ground, with a width of no less than 50 centimeters.














Phone Consultation