YXK-III Remote Control Ignition Device Instructions
One,Product Introduction:
YXK-IIIRemote Control Ignition DevicePrimaryAutomated electrical ignition devices for drilling operations, gas, and fuel-burning burners, featuring semiconductor ignition tips for high output energy, reliable ignition, and resistance to contamination.
This remote-controlled automatic ignition system features a portable instrument housing.Combining a high-energy ignition, inverter, battery, smart charger, remote ignition, and manual ignition into one unit. Complete remote automatic ignition systemSystem consists of an ignition gun (ignition rod), ignition cable, explosion-proof high-energy ignition device, power frequency cable, on-site remote control ignition control box, and remote controller.
YXK-III Remote Control Ignition DeviceBuilt-in24VDCBattery, with external connection220VACThe power supply can charge the battery. The igniter is also equipped with a remote ignition device, which can be500Please provide the Chinese content that needs to be translated into American English.1000Remote ignition within a 10-meter range. (Additionally, pressure switches and flame detectors can be installed on the pipeline to achieve unmanned, fully automatic ignition.) Therefore, this product is particularly suitable for igniting oil, drilling and production venting torches. For diesel field ignition, the igniter is activated through a remote ignition device. The atomized diesel is sprayed out under pressure, and the diesel can be ignited directly by the ignition rod.
YXK-IIIRemote Control Ignition DeviceA dedicated real-time battery voltage monitoring circuit has been installed. When the battery voltage is too low, the monitoring module emits an alarm signal to remind users to charge promptly.
Section II: Main Technical Parameters of Remote Automatic Ignition System:
1Operating Voltage: 220VAC 50Hz
2Ambient Temperature: -40~80℃
3Power Consumption: 2W in standby, 200W at ignition
4Charging Time: ≥10-12h
5Battery:24VDC 2.3Ah
6Continuous ignition time (battery fully charged): 6 to 8 seconds per ignition. Rest for 3 seconds. Repeat this cycle.
7Ignition output high voltage: ≤2500V
8Ignition Energy: ≥20J, Spark Discharge Frequency: ≥12 times/s, Ignition DeviceExplosion-proof type, with an explosion-proof rating of EXdIIBT4 and a safety protection rating of IP56.
9Automatic Ignition: Can be remotely controlled to ignite automatically through a remote switch or relay contact closure; contact switch capacity ≥ 250VAC/3A
10Manual ignition: Operated by a manual button on the controller, with ignition duration controlled manually.
11Dimensions:
Control Box: 400mm x 300mm x 180mm; Portable Instrumentation Enclosure
High-voltage Cable: 25m (Customizable to customer requirements)
Ignition Rod: Sizes such as 1.5m are available upon customer request. Special orders can be accommodated for unique requirements.
Section 3: Case Description:
There are three indicator lights on the panel:
1Ignition indicator light: The light illuminates during ignition.
2Charging indicator light: Illuminates when the smart charger is in charging mode
3Work Indicator Light: Illuminates when the power switch is turned on
Additionally, the right side of the housing features a high-voltage output connector and an AC 220V power input socket.
Section 4: Usage Instructions:
1、 Secure the ignition rod first, then connect the ignition rod, high-voltage wiring, explosion-proof high-energy ignition, wire spool, and remote control box. Then turn onZY-150TypeLocal remote automatic ignition control boxTurn the power switch to the "ON" position and then press the "ignition" button or the remote control button to start the ignition.
2、 Connect the liquefied gas pipeline and cylinder.
3、 Try the liquid gas, ignite using the remote control or with an ignition gun. The gas will automatically ignite upon contact.
4、 Upon seeing the successful ignition, release the remote control. The ignition gun stops igniting.
5、 Charge the remote control box when necessary.ZY-150TypeRemote-controlled automatic ignition control box for on-site use"Set the 'Charge' switch to the 'ON' position, the internal charger will start charging the battery and automatically stop when fully charged.
6、 Place the remote control on the cabinet panel after use, and close the cabinet lid to prevent the remote control from being lost.
V. Cautionary Notes:
1、 Handle the equipment with care to avoid damage.
2、 Charge the battery for at least 8 hours before using it if it has been unused for a long time.
3、 Please charge the battery promptly when it is low on power.
4、 The high-voltage output socket cannot be connected to any electrical equipment other than this device.