- AllProduct Category
-
Underground Coal Mine Emergency Lockout Switch
Mine Emergency Lockout Switch
Drift Sensor
Mine-Use Intrinsically Safe Runaway Sensor
Coal Stack Sensor
Mine-Used Explosion-Proof Electromagnetic Valve
Mine-Used Intrinsically Safe Encoder
BQH18(A) Intrinsic Safety Encoder for Mining
Mine-Use Intrinsically Safe Speed Sensor
Essential Safety Power Supply
Mine-Used Explosion-Proof Low-Voltage Cable Junction Box
Speed Measuring Device
Hydraulic Socket Nut
Explosion-proof Box


详情描述
GUJ25 Coal Accumulation Sensor

I. Main Applications
The GUJ25 Coal Pile Sensor (hereinafter referred to as the Coal Pile Sensor) is suitable for environments with explosive hazards such as coal dust in coal mines, for monitoring material blockages at unloading and transfer points, as well as the material level in intermediate coal bins. It is designed to be connected to intrinsically safe systems for signal control, "used in circuits that have passed intrinsically safe inspections." When the Coal Pile Sensor detects a coal pile signal, the belt conveyor will emit a signal to control power-off and stop. The Coal Pile Sensor can also be used in non-explosive locations on the ground, such as steel mills, cement plants, power plants, ports, and docks, where belt conveyors are present.
Part II: Environmental Conditions for Use
The coal stack sensor should operate reliably under the following conditions:
a. Environmental temperature: -10~+40℃
b. Average relative humidity not exceeding 95% (+25℃).
c. Atmospheric Pressure: 80~106 KPa
d. Applications with no significant vibration or shock.
e. In environments where there is no severe dripping, pooling, or corrosive gases that damage insulation.
f. Working in environments with explosive mixtures of methane and coal dust underground in coal mines.
Section 3: Explosion-Proof Styles
Explosion-proof Type and Marking: Explosion-proof Type: Intrinsic Safety Type for Mining, Mark: Ex ibⅠMb
Section 4: Model Meaning

Five: Dimensions, Weight, and Installation Sizes
a. Dimensions (Length x Width x Height): 327 mm x 130 mm x 56 mm.
b. Weight: Approximately 1kg.
c. Installation Dimensions: Fixed screw center distance is 50 mm ± 1 mm.
Section 6: Outline Drawing

Section 7: Technical Data
a. Action force of the contact rod: ≤9.8N
b. Action Angle: 25° ± 3°
c. Reset Angle: ±5° from 10°
d. Action Direction: Omnidirectional
e. Contact Rating: DC24V/1A (Resistive Load)
f. Cable outer diameter: Φ12mm
g. Number of outlet spouts: 2 pieces;
询价单