VSL-KR Dual-line Distributor_SupplyPro Co., Ltd._Nantong Oudeke Metallurgy Technology Co., Ltd.
Nantong Oudeke Metallurgy Technology Co., Ltd.

Electric Lubrication Pumps | Centralized Lubrication Systems | Multi-point Oi...

0513-83759989 18862826989

VSL-KR Dual-line Distributor

产品Price 65.00/Piece

最小起订Quantity:1 Piece 供货总Quantity: 99999 Piece

用手机扫描二维码直达商品手机版
MobileView details
Location:
Jiangsu/Nantong
有效期至:
长期有效
最后更新:
2024-12-31 14:10
Product Details

VSL-KR Series Dual Line Distributor (40MPa)

I. Terms of Use

The VSL-KR type dual-line distributor features oil supply ports on both the top and bottom. When the distributor piston moves forward and backward, grease is discharged from the top and bottom supply ports, respectively. Inside the corresponding top and bottom supply ports, there is a combined oil drain structure. To change the odd-numbered oil supply, simply unscrew the screw inside the hole. The operation of the distributor can also be directly observed from the indicator rod's movement. Additionally, the oil supply quantity to each outlet can be adjusted within the specified range by adjusting the screws.

This type of distributor is suitable for a two-line dry oil centralized lubrication system with a nominal pressure of 40MPa. Under the action of alternating supply pressure from two main supply lines, it directly controls the piston movement by the supply pressure to dispense grease quantitatively to the lubrication points.


II. Technical Specifications

Use grease with a penetration not less than 265 (25°C, 150g) 1/10mm (NLGI 0#-2#) or oil with a viscosity grade greater than N68; operating temperature range is -10 to 80°C; when using oil as the medium, operate at a pressure of 20MPa.


3. Model Description

Four: Dimensions

Section 5: Instructions for Use

If a corresponding upper and lower outlet merge is required, simply unscrew the pressure nut inside the upper oil outlet with a 6mm Allen wrench, remove the separator sleeve and insert it with the open end facing down, then retighten the pressure nut. At this point, seal the upper outlet with a G1/4 plug to prevent dust from entering.

 

Section 6: Order Instructions

The installation and operation environment temperature of the distributor must be noted in the purchase contract if it is outside the range of -10 to 80°C, to ensure the provision of oil seals that can withstand low and high temperatures during supply.

询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 

Phone Consultation

Consultation Phone:
0513-83759989

Back to Top