Product Details

Ex-proof marking:

Dielectric strength:

≥2000V/min non-breakdown

Insulating Resistance:

≥50 MΩ/hm

The heating element of the constant power parallel electric trace heater is a tightly and uniformly wound heating wire around the insulated busbar. The heating wire is connected sequentially to the busbar at fixed intervals (heating section length), forming a parallel circuit with stable power along the length of the busbar upon voltage application.

In constant power parallel heating cables, continuous heating resistive wires form a series of continuous parallel heating sections – heating sections, each of which is independently operable and can be cut to size as required (except for fire-resistant constant power parallel heating cables).

Constant power parallel heating cable products cannot be used alone; they must be paired with a suitable explosion-proof temperature controller and accessories that are compatible with the environment.

In areas with explosive gas T4 groups in Factory Zones 1 and 2, the explosion-proof temperature controller's set temperature should not exceed 110°C. The temperature sensor is mounted on the outer sheath at a high temperature point to ensure the surface temperature of the electric heating tape does not exceed 130°C.


Constant Power Parallel Cable Heater Structural Diagram


1. Constant Power Parallel Heating Cable Model Description


2. Constant Power Parallel Electric Heat Tracing Main Technical Parameters

ModelSingle-phase constant powerHigh Temperature Single Phase Constant PowerThree-phase constant power
ProjectParallel electric heating tapeRatio parallel heating cableParallel electric heating tape
Rated Output Power10/15/20/25/30/35/40/45/50/55/60 W/m
Explosion-Proof MarkingEx e IIC T4 Gb
Rated Voltage220V220V380V
Dielectric Strength:≥2000V/min non-breakdown
Insulation Resistance:≥50MΩ/hm
High temperature resistance.205℃260℃205℃
Low installation temperature:≥-40℃


3. Constant Power Parallel Electric Heat Tracing Performance Comparison Table

ProjectTemperature Resistance GradeMaintain temperatureUtilize length
Model
RDP2-(Q)-J3-10205℃≤150℃195 m
RDP2-(Q)-J3-20205℃≤120℃140 m
RDP2-(Q)-J3-30205℃≤90℃115 m
RDP2-(Q)-J3-40205℃≤65℃90 m
RDP2-(Q)-J4-20260℃≤180℃140 m
RDP2-(Q)-J4-30260℃≤150℃115 m
RDP2-(Q)-J4-40260℃≤120℃90 m
RDP3-(Q)-J3-30205℃≤120℃275 m
RDP3-(Q)-J3-40205℃≤100℃235 m
RDP3-(Q)-J3-50205℃≤80℃210 m
RDP3-(Q)-J3-60205℃≤60℃180 m


4. Application Sites:

Constant power parallel electric heating cables are suitable for pipeline and equipment frost and condensation prevention in the following situations:

· Safe Zone;

· Hazard Zones 1 and 2; Zones 21 and 22;

·Humid, salt fog environment; corrosive environment.

询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

Phone Consultation

Consultation Phone:
400-8280580

Back to Top