Three-phase constant power electric trace heating_SupplyPro Co., Ltd._Wuxi Global Electrical Equipment Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Wuxi Global Electrical Equipment Co., Ltd.

Electric Trace Heating, Skin Heating Cable, MI Heating Cable, Various Electri...

400-8280580 18061582653

Three-phase constant power electric trace heating

产品Price Negotiable

最小起订Quantity: 供货总Quantity:

用手机扫描二维码直达商品手机版
MobileView details
Location:
Jiangsu/Wuxi
有效期至:
长期有效
最后更新:
2024-10-17 10:36
Product Details

Explosion-Proof Marking:

Dielectric strength:

≥2000V/min non-breakdown

Insulation Resistance:

≥50 MΩ/hm

The heating element of the constant power parallel electric heater is a tightly and uniformly wound heating wire around the busbar insulation. The heating wire is connected to the busbar sequentially at fixed intervals (heating section length), forming a stable parallel circuit along the length of the busbar when voltage is applied.

In constant power parallel heating cables, continuous heating resistive wires form a series of interconnected parallel heating sections – heating sections, each of which is independently separable for trimming according to requirements (except for fire-resistant constant power parallel heating cables).

Constant power parallel electric heating cables cannot be used alone; they must be paired with a explosion-proof temperature controller and explosion-proof accessories that are compatible with the environment.

In areas of Factory Zone 1 and 2 with explosive gas T4 groups, the explosion-proof temperature controller's set temperature should not exceed 110°C. The temperature sensor is mounted on the outer sheath at a high temperature point to ensure the surface temperature of the electric tracing heating does not exceed 130°C.

Constant Power Parallel Heating Cable Structure Diagram


1. Constant Power Parallel Electric Heating Cable Model Description


2. Main Technical Parameters of Constant Power Parallel Electric Heat Tracing

ModelSingle-phase constant powerHigh Temperature Single-Phase Constant PowerThree-phase Constant Power
ProjectParallel electric heating tapeRatio-connected electric heating tapeParallel electric heating tape
Rated Output Power10/15/20/25/30/35/40/45/50/55/60 W/m
Explosion-Proof MarkingEx e IIC T4 Gb
Rated Voltage220V220V380V
Dielectric Strength:≥2000V/min Non-breakdown
Insulation Resistance:≥50MΩ/hm
High temperature resistance205℃260℃205℃
Low installation temperature:≥-40℃


3. Constant Power Parallel Electric Heating Cable Performance Comparison Table

ProjectTemperature Resistance GradeMaintain temperatureUtilize length
Model
RDP2-(Q)-J3-10205℃≤150℃195 m
RDP2-(Q)-J3-20205℃≤120℃140 m
RDP2-(Q)-J3-30205℃≤90℃115 m
RDP2-(Q)-J3-40205℃≤65℃90 m
RDP2-(Q)-J4-20260℃≤180℃140 m
RDP2-(Q)-J4-30260℃≤150℃115 m
RDP2-(Q)-J4-40260℃≤120℃90 m
RDP3-(Q)-J3-30205℃≤120℃275 m
RDP3-(Q)-J3-40205℃≤100℃235 m
RDP3-(Q)-J3-50205℃≤80℃210 m
RDP3-(Q)-J3-60205℃≤60℃180 m


4. Applicable Locations:

Constant power parallel electric heating tape is suitable for pipe and equipment frost and condensation prevention in the following situations:

·Safe Zone

· Hazard Zones 1 & 2; Zones 21 & 22;

·Moist and salt spray environments; corrosive conditions.