High-Temperature Single-Phase Constant Power Electric Heat Tracing Cable_SupplyPro Co., Ltd._Wuxi Global Electrical Equipment Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Wuxi Global Electrical Equipment Co., Ltd.

Electric Trace Heating, Skin Heating Cable, MI Heating Cable, Various Electri...

400-8280580 18061582653

High-Temperature Single-Phase Constant Power Electric Heat Tracing Cable

产品Price Negotiable

最小起订Quantity: 供货总Quantity:

用手机扫描二维码直达商品手机版
MobileView details
Location:
Jiangsu/Wuxi
有效期至:
长期有效
最后更新:
2024-10-16 11:19
Product Details

Explosion-Proof Marking:

Dielectric strength:

≥2000V/min non-arc breakdown

Insulation Resistance:

≥50 MΩ/hm

The heating element of the constant power parallel electric heating tape is a tightly and uniformly coiled heating wire wrapped around the busbar insulation. The heating wire is connected to the busbar sequentially at fixed intervals (heating section length), forming a stable parallel circuit along the length of the busbar after voltage is applied.

In constant power parallel heating cables, continuous heating resistive wires form a series of interconnected parallel heating sections – heating sections, each of which is independently operable and can be cut to size as required (except for fire-retardant constant power parallel heating cables).

Constant power parallel heating cables cannot be used alone; they must be paired with a suitable explosion-proof temperature controller and accessories that match the environment.

In areas of Factory Zone 1 and Zone 2 with explosive gas T4, the explosion-proof temperature controller is set not to exceed 110°C. The temperature sensor is mounted on the outer sheath at a high temperature point to ensure the surface temperature of the electric tracing does not exceed 130°C.

Constant Power Parallel Electric Heating Cable Structure Diagram


1. Constant Power Parallel Electric Heat Tape Model Description


2. Key Technical Parameters of Constant Power Parallel Electric Heating Tape

ModelSingle-phase constant powerHigh-temperature Single-Phase Constant PowerThree-phase Constant Power
ProjectParallel electric heating tapeThermal Cable for Parallel ConnectionParallel electric heating tape
Rated Output Power10/15/20/25/30/35/40/45/50/55/60 W/m
Flameproof MarkEx e IIC T4 Gb
Rated Voltage220V220V380V
Dielectric Strength:≥2000V/min non-breakdown
Insulation Resistance:≥50MΩ/hm
High temperature resistance205℃260℃205℃
Low installation temperature:≥-40℃


3. Constant Power Parallel Electric Heating Cable Performance Comparison Table

ProjectTemperature Resistance GradeMaintain temperatureUtilize length
Model
RDP2-(Q)-J3-10205℃≤150℃195 m
RDP2-(Q)-J3-20205℃≤120℃140 m
RDP2-(Q)-J3-30205℃≤90℃115 m
RDP2-(Q)-J3-40205℃≤65℃90 m
RDP2-(Q)-J4-20260℃≤180℃140 m
RDP2-(Q)-J4-30260℃≤150℃115 m
RDP2-(Q)-J4-40260℃≤120℃90 m
RDP3-(Q)-J3-30205℃≤120℃275 m
RDP3-(Q)-J3-40205℃≤100℃235 m
RDP3-(Q)-J3-50205℃≤80℃210 m
RDP3-(Q)-J3-60205℃≤60℃180 m


4. Applicable Locations:

Constant power parallel heating cables are suitable for pipeline and equipment frost and condensation prevention in the following situations:

· Safe Zone;

· Hazardous Area 1, 2; Zones 21, 22;

·Humid, salt fog environments; corrosive conditions.

询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

Phone Consultation

Consultation Phone:
400-8280580

Back to Top