Electric Trace Heating, Skin Heating Cable, MI Heating Cable, Various Electri...
产品Price Negotiable
最小起订Quantity: 供货总Quantity:
Explosion-Proof Marking: |
|
Dielectric strength: |
≥2000V/min non-arc breakdown |
Insulation Resistance: |
≥50 MΩ/hm |
The heating element of the constant power parallel electric heating tape is a tightly and uniformly coiled heating wire wrapped around the busbar insulation. The heating wire is connected to the busbar sequentially at fixed intervals (heating section length), forming a stable parallel circuit along the length of the busbar after voltage is applied. In constant power parallel heating cables, continuous heating resistive wires form a series of interconnected parallel heating sections – heating sections, each of which is independently operable and can be cut to size as required (except for fire-retardant constant power parallel heating cables). Constant power parallel heating cables cannot be used alone; they must be paired with a suitable explosion-proof temperature controller and accessories that match the environment. In areas of Factory Zone 1 and Zone 2 with explosive gas T4, the explosion-proof temperature controller is set not to exceed 110°C. The temperature sensor is mounted on the outer sheath at a high temperature point to ensure the surface temperature of the electric tracing does not exceed 130°C. Constant Power Parallel Electric Heating Cable Structure Diagram 1. Constant Power Parallel Electric Heat Tape Model Description 2. Key Technical Parameters of Constant Power Parallel Electric Heating Tape 3. Constant Power Parallel Electric Heating Cable Performance Comparison Table 4. Applicable Locations: Constant power parallel heating cables are suitable for pipeline and equipment frost and condensation prevention in the following situations: · Safe Zone; · Hazardous Area 1, 2; Zones 21, 22; ·Humid, salt fog environments; corrosive conditions.

Model Single-phase constant power High-temperature Single-Phase Constant Power Three-phase Constant Power Project Parallel electric heating tape Thermal Cable for Parallel Connection Parallel electric heating tape Rated Output Power 10/15/20/25/30/35/40/45/50/55/60 W/m Flameproof Mark Ex e IIC T4 Gb Rated Voltage 220V 220V 380V Dielectric Strength: ≥2000V/min non-breakdown Insulation Resistance: ≥50MΩ/hm High temperature resistance 205℃ 260℃ 205℃ Low installation temperature: ≥-40℃ Project Temperature Resistance Grade Maintain temperature Utilize length Model RDP2-(Q)-J3-10 205℃ ≤150℃ 195 m RDP2-(Q)-J3-20 205℃ ≤120℃ 140 m RDP2-(Q)-J3-30 205℃ ≤90℃ 115 m RDP2-(Q)-J3-40 205℃ ≤65℃ 90 m RDP2-(Q)-J4-20 260℃ ≤180℃ 140 m RDP2-(Q)-J4-30 260℃ ≤150℃ 115 m RDP2-(Q)-J4-40 260℃ ≤120℃ 90 m RDP3-(Q)-J3-30 205℃ ≤120℃ 275 m RDP3-(Q)-J3-40 205℃ ≤100℃ 235 m RDP3-(Q)-J3-50 205℃ ≤80℃ 210 m RDP3-(Q)-J3-60 205℃ ≤60℃ 180 m

Phone Consultation