详情描述

DO30-E+ | DO30E+ | DO30B-3 | Digital Multimeter Calibrator, Multimeter Calibration Tool, Triple Meter Checker, Triple Meter Calibrator
I. Usage, Features:
DO30-E+ Digital Triple-Function Meter Calibrator, Multi-Function Calibration Instrument is suitable for calibration of various 0.5-class and below current, voltage, and multi-meters. It can also be used as a high-stability test power supply, paired with high-grade standard meters, for calibration of 0.5-class and above current and voltage meters.
II. Main Functions:
1. 5 1/2-digit LED digital display for output quantity, available in both actual value and percentage formats.
2. DC and AC current output range: 0~100uA~500uA~2mA~5mA~20mA~50mA~200mA~500mA~2A~5A~20A.
3. Output voltage range for AC and DC: 0 to 200mV to 1V to 2V to 5V to 10V to 20V to 50V to 100V to 200V to 500V to 1000V.
4. Available frequency options include three types: 50Hz, 60Hz, and 400Hz
5. Overload protection with automatic shutdown and manual reset.
6. Each voltage and current rating can withstand an overload of 20%.
7. Clamping meter measurement function: Equipped with our standard coil, capable of measuring AC 0-1000A; error ±0.3%.
Appendix:

Export ItemsOutput RangeRated OutputPeak OutputAccuracy
AC/DC Voltage0~200mV10mA30mADC: ±(0.02% of reading + 0.03% of full scale)
AC: ±(0.03% of reading + 0.07% of full scale)
0~2V20mA60mA
0~5V~10V~20V40mA100mA
0~200V~500V20mA60mA
0~1000V10mA30mA
AC/DC Current0~100uA~500uA ~2mA~5mA ~20mA~50mADC:3V   AC:36V

DC: ±(0.02% of reading + 0.05% of full scale)
AC: ±(0.03% of reading + 0.07% of full scale)
Below 2mA, accuracy is not assessed.

0~200mA ~500mADC:3V AC:12V
0~2A~5A~20A2V
Standard Resistor20, 24, 50, 100, 240, 500 Ω | 1, 2.4, 5, 10, 24 KΩ | Additional ×1K, ×1 range (i.e., 10KΩ~24MΩ)    0.25W
    ±0.3%+20mΩ

Section 3: Technical Specifications:
1. Stability: DC < fullRange0.01% per 2 minutes, AC < fullRange0.03%/2 minutes
2. Communication Distortion: <0.5%
3. DC Ripple Factor: <0.1%
4. Output Frequency & Accuracy: 50Hz/60Hz/400Hz < 1%
5. Output voltage, current range, and accuracy (at 23℃±2℃, output value greater than 10%)Range
6. Power Consumption: AC voltage 220V ± 10%, frequency 50Hz ± 1Hz; power consumption < 180VA
7. Working Environment: Temperature between 5°C and 35°C, relative humidity not exceeding 80%
8. Office Hours: Continuous
9. Dimensions: 135×480×420mm³
Weight: Approximately 16kg


询价单

主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》