- AllProduct Category
-
HG30 Series Multi-Function Calibrator
DO30 Series Multi-Function Meters Calibration Device
XF30 Series Multi-Function Calibrator
HGZX Series Standard Resistor Box
HGGC Series Process Verifier
Megohmmeter Calibration Equipment
Three-Phase Multi-Function Standard Power Supply
HGSZ Series Distortion Meters
Fluke Precision Digital Multimeter
Huaguang Measuring Instruments Series
HG30 Series Multi-functional Calibrator


详情描述
1. AC/DC voltage output range:0~250mV~1V~2.5V~5V~10V~25V~50V~100V~250V~500V~1000VOutput Voltage1100V.
2. DC and AC current output range:0~ 50uA~100uA~500uA~2.5mA~10mA~25mA~100mA~250mA~1A~2.5A~10A~50AOutput55A.
3. In addition to the standard source calibration range, the range can be arbitrarily expanded via the range key, for example:250 mVFile can be expanded to75 mV、100 mV、125 mV、150 mV、200 mV、250mV.
4. Standard source output frequency with six steps:50Hz、60Hz、100 Hz、400Hz、800Hz、1000HzCustom Instrument45Hz-1100 HzAdjustable as needed).
5. Standard resistors include:10Ω、100Ω、1kΩ、10kΩ、100kΩ、1MSix gears.
6. Output AC/DC voltage and current adjustment range: better than full scale1×10-5Each range is available10-110%Between adjustment1000VRange adjustment is available.10-100 %), each of the six digits can be individually adjusted, with continuous step progression.
7. Communication Frequency Accuracy: ±0.02% 。
8. Output distortion less than0.5% 。
9. Output DC Ripple Less Than0.5% 。
10. Power Supply220V(±10%), Frequency50 Hz(±10%), Power Consumption120VA。
11. Application Environment: Temperature20±5°C, Relative Humidity80%No direct sunlight, no electromagnetic interference.
12. Output voltage, current, standard resistance range, and accuracy23℃±2As shown in the table:
Output Project | Output Scope | Rated Output | Output | Accuracy |
Trade and Direct Flow Voltage | 0~75mV~250mV | 10mA | 30mA | DCV:±(Reading value0.02%+Full range0.03%) ACV: ±(Reading Value0.02%+Full range0.03%) DCI: ±(Readout value0.02%+Full range0.03%) ACI: ±(Reading value0.02%+Full range0.03%) AC Voltage Additional Error: ±0.02mV ACI:≤1mANo precision assessment |
0~1V~2.5V | 20mA | 60mA | ||
0~5V~10V~25V~50V | 40mA | 100mA | ||
0~100V~250V~500V | 20mA | 60mA | ||
0~1000V | 10mA | 30mA | ||
Trade & Direct Current to current | 0~100uA~500uA~2.5mA~10mA~25mA~100mA | DC:3V AC:36V | ||
0~250mA | DC:3V AC:12V | |||
0~1A~2.5A~10A | 2V | 4V | ||
0~50A~60A | 1.5V | |||
Label Please provide the Chinese content to be translated. Electricity Block | 10Ω、100Ω、1kΩ、10kΩ、100kΩ、1MΩ | 0.25W | ±0.2%+20mΩ | |
Note:(1) Working environment temperature exceeds23℃±2°C, every change10°C, additional error less than the basic error of this range (2)400Hz~1.1KHz± (Error)0.15%Reading+0.2%Range | ||||