HG30 Series Multi-functional Calibrator


详情描述
I. Purpose and Features:
HG30 ModelMulti-functional Calibration InstrumentIt is an intelligent AC/DC standard voltage, current, and frequency calibrator (where the AC output is displayed as true RMS). The instrument features four display windows, allowing simultaneous display of actual output values, percentages, the meter's full-scale value, and output frequency. The instrument's output can be set based on the meter's full-scale value.RangeAnd the stepping amount can be selected according to the scale of the inspected table. Output adjustment options are available.Keyboard(Keypad) Control or Potentiometer Control. Features digital display, error direct reading,RangeWide range, fine gradation, high precision, excellent stability, and easy operation. Suitable for calibration, inspection, and maintenance of 3.5-digit digital multimeters, various 0.2-class and below pointer-style AC and DC voltage, and current meters; also serves as a high-stability test power source, paired with high-grade standard meters to calibrate 0.1-class current and voltage meters.
II. Main Functions:
1 、5 1/2LED digital display with output quantity shown in both actual value and percentage.
2. UtilizeKeyboardControl the increase and decrease of output quantity.KeyboardControl ratios are 100/N, 10%/N, 1%/N, 0.1%/N (where N is 4, 5, 6, 10, 15).
3 、External Control RegulatorThe controller allows for off-line adjustment of output quantity increments.KeyboardBoth configurations available, easily switchable.
4. AC and DC voltage output range is 0 to 1050V.
5. AC and DC current output range is 0 to 20A.
6. Offer adjustable output frequency: 4-digit LED display, continuously adjustable from 40Hz to 1200Hz, utilizing digital technology to ensure accuracy and stability of the frequency.
7. Overload protection with automatic shutdown and manual reset.
8. Automatically select 60Hz frequency during AC output. Automatically select 1000Hz during DC output.
9. Clamp Meter Measurement: Equipped with our standard coil, capable of measuring 0-1000A current with an accuracy of ±0.3%.
III. Technical Performance:
1. Stability: AC < fullRange0.02%/5 minutes
DC < FullRange0.01%/5 minutes
The instrument must be preheated for two hours when making precise measurements.
2. Communication Distortion: <0.5%
3. Direct Current Ripple Factor: <0.05% (at rated output)
4. Output frequency accuracy: 40Hz-1200Hz < 0.1%
5. Output voltage and currentMedian ResistanceScope and accuracy are as shown in (Appendix 1).
6. Power Specifications: AC Voltage 220V ±10%, Frequency 50Hz ±1Hz
7. Working Environment: Temperature 5°C to 35°C, relative humidity <80%
8. Office Hours: Continuous
9. Dimensions: 135×460×420mm3
10. Weight: Approximately 16 kg
Export Items | Output Range | Rated Output | Peak Output | Accuracy | |
AC/DC Voltage | 0~250mV | 10mA | 30mA | Basic Error: (50Hz - 500Hz) DC: ±(0.02% reading + 0.03% range) AC: ±(0.02% reading + 0.03% range) Voltage below 100mV and current below 2mA are not assessed for accuracy. (500Hz-1200Hz) AC Current Additional Error: ±0.2% Range AC Voltage Additional Error: ±0.2% Range | |
0~2.5V | 20mA | 60mA | |||
0~5V~10V~25V | 40mA | 100mA | |||
0~250V~500V | 20mA | 60mA | |||
0~1000V | 10mA | 30mA | |||
AC/DC Electric Current | 0~100mA~500uA~2mA~5mA~20mA~50mA | DC:3V AC:36V | |||
0~200mA~500mA | DC:3V AC:12V | ||||
0~2A~5A~20A | 2V | ||||
Median Resistance | 10、24、50、100、240、500(Ω)1、2.4、5、10、24(kΩ) Additional ×1000, ×1 range steps (i.e., 10kΩ~24MΩ) | 0.25W | ±0.2%+20mΩ | ||
Note: (1) For an operating environment temperature exceeding 23℃ ± 2℃, the additional error is less than the basic error of the range for every 10℃ change. (2) 20A/1000V: ±(0.15% of reading + 0.2% of range) error at 500Hz-1200Hz | |||||