HG3060-100Standard Type Three-Phase Test Source|Three-phase standard source|Three-phase power source|Multi-functional three-phase power supply

One, Product Overview

Dear customer, we are delighted to have you choose ourHG3060-100Standard three-phase test source product, capable of generating adjustable amplitude, phase, frequency, and stable power three-phase AC voltage and current signals.

Primarily for testing and calibration of digital electrical measuring instruments such as electricity meters, voltage meters, current meters, phase meters, frequency meters, power meters, power factor meters, and power factor meters, as well as for testing and calibration of electrical sensors like voltage transformers, current transformers, and clamp-on current transformers; and for testing and calibration of power transmitters, current transmitters, power transmitters, power factor transmitters, and frequency transmitters. Additionally, for testing and calibration of equipment such as reactive power compensation controllers, power data collectors, electricity meter on-site verification instruments, power parameter test instruments, voltage monitors, distribution load monitors, multi-functional power meters, load management terminals, voltage and current loss timers, and distribution automation terminals.

This power product is designed with high-precision sampling technology and incorporates advanced digital signal processing methods, among other techniques.Advanced technology, superior performance, compact size, lightweight, easy to carry, suitable for both lab and field use. We believe you will be satisfied with this high-quality power product.

Before using this product, please carefully read the enclosed user manual. The following are the precautions to be taken when using this product:

     1Do not shut down or reset the equipment while voltage and current are being output. Especially when high voltage and large currents are being supplied, first turn off the signal output through the operation buttons, and then switch off the power supply to the instrument.

2Output voltage must not be short-circuited, and output current must not be open-circuited; before the operator initiates the output voltage signal and current signal, ensure that the external connections are correct and there are no exposed parts in the external wiring section. Turn off the signal output when temporarily leaving.

3Ensure proper grounding of the instrument when using this product.

4Before measurement or calibrationMake sure to preheat this instrument.10Minutes; otherwise, the indicators may be affected.

5Do not open the instrument without permission from our company; it contains high voltage and poses a risk of electric shock.

6We assume no responsibility for any consequences arising from the violation of the aforementioned precautions.

II. Main Features and Characteristics

1Voltage, current, phase, power, power factor, and frequency all provide high-precision, high-stability standard signal outputs with software closed-loop control.

2Voltage, current, and phase adjustment are available for both three phases or any single phase simultaneously.

3Phase differences between three-phase voltages and between each phase's voltage and current are adjustable.360°Adjustment.

4Three-phase, four-wire/Three-phase, three-wire, positive phase sequence/Four reverse phase sequence states can be arbitrarily combined for output.

5Implement800×600Large, touch-sensitive LCD screen with real-time display capabilities.32Power parameters.

6The touch screen and front panel are equipped with operation buttons, all clearly visible. Common test points for voltage, current, and power factor are set up, allowing one-touch access for convenient and quick operation.

7Instant input feature simplifies the operation process.

8Can be paired with supervisory communication software, allowing for whole machine operation via the supervisory computer, with open communication protocols.

9In case of voltage short circuit, current open circuit, or wiring error, the output can be automatically stopped with an accompanying sound and light alarm.

10Utilizing advanced power amplifier technology, reliability and stability are significantly enhanced.

Section 3: Main Technical Specifications

1AC Voltage Output

HardwareRange380V220V100V57.7V

Adjustment Range:(1-120)%RG         Adjust fineness:0.01%RG

Accuracy:0.1%RG              Stability:≤0.02%/2min

Output Load: Per Phase20VA         Load Adjustment Ratio:0.01%

Distortion:≤0.3%(Non-reactive load)

2交流电流输出: AC Current Output

HardwareRange100A20A5A1A0.2A0.05A

Adjustment Range:  (1120)%RG       Adjust fineness:  0.01%RG

Accuracy:   0.1%RG             Stability:   ≤0.02%/2min

Output Load: Each phase150VA (MAX /100A)     Load Adjustment Rate: 0.01%

Distortion:   ≤0.3%(Non-reactive load)

3With power output

Accuracy:   0.1%RG           Stability: 0.02%RG/2min

4Phase

Adjustable Range:  359.99°   Adjust fineness: 0.02°   

Accuracy: 0.05°

5Frequency

Adjustment Range: 20Hz80Hz   Adjust fineness: 0.001Hz   

Accuracy: 0.01Hz

6Power Factor

Adjustment Range: -10+1       Adjust fineness: 0.001   

Accuracy: 0.001

7Environmental Conditions

Working Environment Temperature: 040

Relative Humidity: ≤85%

      Operating Power Supply: AC220V±15%Peak power consumption400VA

8Dimensions and weight               

Dimensions:449mm×455mm×177mm

Weight: 18Kg