    2024-04-30

    Pipeline management and maintenance, urban planning and construction, and power supply departments require pipeline inspections, which are essential for pipeline maintenance units.

    (1) Feature-rich

    Transmitter Function: Equipped with three signal application modes—inductive, direct, and clamp—suitable for various occasions.

    2. Receiver Functionality: Used for measuring the location, direction, burial depth, and current of underground cables.

    3. Left and right positioning arrows indicate the target pipeline location, with quick positioning.No Chinese content provided.. Confirm; Forward and backward arrowsThe decibel (dB) value indicates the location and size of the coating's damage point.

    4. Backlit feature for night-time emergency use.

    5. Underground Cable Fault LocationPlease provide the Chinese content to be translated.. SurePositioning.

    6. Current Measurement: Measures the current applied by the transmitter to the pipeline under test.

    7. Multimeter Functionality: Measures output voltage, line voltage, line current, impedance, and power. Tests the continuity and insulation quality of cables before and after cable fault detection.

    8. External Inductive Clamp: Ideal for situations where direct signal application is not possible during cable detection.

    (High) Precision in Positioning:

    Multiple measurement modes for pipeline location(Valley Mode, Peak Mode, Wide Peak Mode, Peak Arrow Mode), intergradable for verification, ensuring pipeline positioning accuracy.Please provide the Chinese content to be translated.. SureDegree

    1、Extreme.Large Value MethodThe horizontal component or gradient changes can be measured using the Peak Mode, Wide Peak Mode, and Peak Arrow Mode, with the location of the highest value determining the positioning.

    2、Extreme.Xiaozhi MethodUtilizing the valley value pattern, the location is determined by measuring the change in the vertical component and identifying the position of its minimum value.

    (III) Various Depth Measurement Methods

    A variety of depth measurement methods are available for selection., and can be mutually verified.

    Dual-level Coil Direct Reading Method

    2. Single horizontal coil 80% method, 50% method

    3. The 45-degree method.

    Strong anti-interference capability

    1. Multi-parametric observation: Measures both horizontal and vertical components, as well as horizontal gradients.

    2. High transmission power: The transmitter outputs up to 10W with continuous adjustable power, allowing for flexible selection based on requirements.

    3. High frequency of work

    Transmitter Frequency:128Hz、512Hz、1KHz、2KHz、8KHz、33KHz、65KHz、83KHz。

    Receiver Frequency: Radio,50Hz、100Hz、512Hz、1KHz、2KHz、8KHz、33KHz、65KHz、83KHz。

    In accordance with the characteristics of the target pipelineMaterial, structure, burial depth, length, etc., and select an appropriate working frequency based on the environment.

    (Simplified Operation)

    Intuitive: Utilizes graphical displays to continuously and in real-time show various parameters and signal strength during the detection process.

    2. Auto: During depth measurement, automatically switch to dual horizontal antenna mode and automatically adjust the receiver sensitivity for optimal signal quality. Upon completion of depth measurement, automatically revert to the original working mode.

    (6) Extended working hours with low operational costs

    The transmitter is equipped with a high-capacity lithium battery pack.A single charge can power field exploration for a full workday, allowing for reusable use, significantly reducing detection costs.

    (7) Dual-Mode Transmitter

    Under normal circumstances, if the transmitter's battery is fully charged, the instrument's internal battery pack is used for power. Should the transmitter's battery run low during use but the detection task is not yet completed, a dedicated power adapter can be directly connected, allowing the instrument to continue functioning without the need to wait for it to recharge fully.

     




Contact us

Wuhan E'dian Electric Power Test Equipment Co., Ltd.
Service Hotline 13808660749
Company Phone 400-034-8088
Company Address North of Guantan Second Road, Qiaokou District, Wuhan, Building 4, 1st Floor, Room 17 (HSBC Corporate Headquarters)

Message Consultation

 Click OK to indicate that you agree to《Service terms》《Privacy policy》

b2b.china9.net © Zhongshang 114 Hebei Network Technology Co., Ltd.Address: Room 6009, Oriental New World Center, No.118 East Zhongshan Road, Qiaoxi District, Shijiazhuang City, Hebei ProvincePlatform Service Hotline: 4006299930

 Click OK to indicate that you agree to《Service terms》《Privacy policy》