Environmental equipment, instruments and meters, robots, ...

Introduction to Digital High Voltage Bridge Cable Fault Tester
GDZ-15The intelligent electrical bridge for cable fault location is based onMURRAYBased on the bridge principle, using a switch-mode power supply to form a high-voltage constant current source, no-load voltage15000VShort-circuit Current5mAThe technology is used for locating the breakdown points and non-breakdown defect points of various wires and cables after laying.
GDZ-15The intelligent electrical bridge for cable fault location employs fully automated testing. After the user inputs the full length of the cable, it can automatically calculate and display the fault distance. Utilizing a color touch LCD screen as both a display and an operation device, it features one-touch operation, completely replacing the traditional high-voltage bridge measurement method. It is easy to use, user-friendly, with both text and graphics, and is safe and reliable.
The digital bridge and digital megohmmeter are combined into one, offering enhanced functionality. It can automatically calculate the system's absorption ratio and polarization index, allows manual setting of test time, and features memory capability to record insulation conditions at different points.
Compared to the B-Reflection Time-Domain Method,KC-15The digital high-voltage bridge cable fault tester is particularly suitable for:
1The high dielectric breakdown point of the laid cable, particularly the linear high dielectric breakdown points that are difficult to achieve low resistance, such as the linear high dielectric breakdown of cable intermediate joints (this is mainly due to the poor manufacturing process of cable joints. Under high voltage application, only leakage and creeping arc discharge occur without breakdown discharge).
2The high-voltage bridge balancing method has no test blind spots, and is used to determine the breakdown points of short cables and those near the cable ends.
3High-voltage bridge method requires only the uniformity of the cable phase wire resistance for measurement. However, cables with poor traveling wave transmission characteristics, such as those with high dielectric losses,PVCLow-voltage cables
KC-15Digital High-Voltage Bridge Cable Fault Tester
Product Features
1Easier to operate
One-Touch Operation: Automatic zeroing, automatic distance measurement, and one-touch test result output. Fewer buttons, easy operation, and overcomes human error.
Automated Testing: High intelligence level, automatically completes location, and automatically calculates fault distance based on the testing ratio.
Wide insulation range testing: unaffected by low current, insulation resistance testing up to150MΩ。
2Advanced technology
Powerful Functionality: Integrated with digital bridge and digital megohmmeter functions, it automatically calculates absorption ratio and polarization index.
Wireless Isolation Technology: Secure and Reliable Communication Operations
Digital Positioning Technology: Full software control, automatic positioning completed, with a clear LCD display.
Test Emergency Stop Technology: Directly press the emergency stop button in an emergency, and the instrument will immediately automatically reduce the voltage to ensure safety.
Automatic Pressure Regulation Technology: One-touch operation for automatic pressure regulation and zeroing, intelligent testing.
3High anti-interference performance:
This technology can prevent test cables from being affected by interference signals from other operational cables, ensuring uninterrupted testing.
4Advanced operational display unit
Color Touch LCD Display: Utilizes a color touch LCD screen for a more intuitive and user-friendly experience.
Touchscreen Keypad Operation: The touch keypad completely replaces buttons, offering a more advanced and convenient experience.
KC-15Digital High-Voltage Bridge Cable Fault Tester Interface Display
Technical Indicators
Digital Bridge:
Test Voltage:0V Please provide the Chinese content you would like to be translated into American English.15000 V
Voltage Grade:1KV、2 KV、5KV、8KV、10KV、12KV、15KVCustomized
Short-circuit Current:5 mA
Tested Resolution:0.1%
Scope of Testing:< 20 km
Working Voltage:AC 220V±10% 50Hz
Touchscreen One-Touch Test Operation
Display Format:800×480(7Color Touch LCD Screen
Interference Resistance: >100VAC
Dimensions:465 mm×330 mm×260 mm
Weight:≤11.2 kg
Digital Megohmmeter
Testing Method Touchscreen one-touch test operation
Voltage Grade :500V、1000V、2500V、5000V、1000V、15000V
Short-circuit Current :5 mA
Resolution :0.1MΩ
Insulation Test High Value:0.1 MΩ--300 MΩ
Insulation Value Memory with Polarization Index Absorption: Automatic Testing for Different Time Periods
The intelligent electric bridge for cable fault location features adjustable technical indicators and can be customized according to user requirements.