Environmental equipment, instruments and meters, robots, ...

The High-Voltage Cable Outer Sheath Fault Tester is a testing system developed by our company to address the issue of multiple grounding faults in the outer sheath of single-core cables in the current trend of high-voltage and ultra-high-voltage transmission within the power system. As ultra-high-voltage transmission lines typically consist of single-core cables (voltage grades of 35KV to 500KV), the metallic sheath is usually grounded at one end or in segmented cross互联 grounding. In the event of a breach in the outer sheath, a significant circulating current can occur, causing damage to the cable's main insulation. In response to the unique grounding method of ultra-high-voltage cable sheaths, this testing system is equipped with a bridge distance measurement section and a step voltage pinpointing section. Through effective combination, it can complete the testing of excessive grounding or leakage current in the outer sheath of ultra-high-voltage single-core cables, as well as significant hidden dangers and high-voltage cable main insulation faults. The equipment has no blind spots during testing, making it highly effective in locating leakage tracking failures in short cables and cable joints, which do not puncture. The entire system meets the requirements for testing high-voltage cable outer sheath faults.
First Technical Indicator:
High Voltage Bridge Tester Technical Specifications
◆ Test Voltage: 0~15kV, Negative High Voltage, Continuously Adjustable ◆ High Current: 30mA
◆Test Ratio Accuracy: ±(0.2%·L±1) meters ◆Operating Power Supply: AC220V±10%
◆ Interference Resistance: >100VAC ◆ Weight: ≤12kg
◆Dimensions: L478mm × W360mm × H316mm
Part Two: Technical Specifications:
◆Technical Parameters of Pipeline Comprehensive Tester
Transmitter technical specifications
◆ Injection Method: 480Hz, 7.7KHz, 31KHz, and 61KHz ◆ Induction Method: 31KHz, 61KHz
◆ Clamping Method: 31KHz ◆ Fault Detection:
◆ Output Voltage: 0-400Vp-p, varies with insulation conditions ◆ Output Waveform: Sine Wave
◆ Power: 11.1VDC 4.4Ah Lithium Battery ◆ High Output Power: 10W
Receiving Equipment Technical Specifications
Power Consumption: <1.0W Power Supply: 11.1VDC 1.8Ah Lithium Battery Insulation Fault Detection: Not less than 2MΩ
◆ Test Line Depth: 5 meters (as normal) ◆ Routing Error of Test Line: ≤5 cm
◆ Test Line Burial Depth Error: ±0.05h ±5cm (h represents the burial depth of the pipeline)
◆ Testing the pipeline route and buried length by injection method: Not less than 20Km (under normal circumstances)
◆ Effectively measure line routing and buried length using inductive testing: not less than 5Km (typically)
◆ Utilizing clamping method to test the effective length of line route and burial depth: not less than 10Km (under normal conditions)
b2b.china9.net © Zhongshang 114 Hebei Network Technology Co., Ltd.Address: Room 6009, Oriental New World Center, No.118 East Zhongshan Road, Qiaoxi District, Shijiazhuang City, Hebei ProvincePlatform Service Hotline: 4006299930