详情描述

Fully Automatic Liquid-Liquid Extraction Instrument CH-CQ-6A, Manual Sample Injection, 6-Position Operating SystemOperating Principle: Utilizes air pressure to thoroughly mix and vigorously collide water samples with extractants to achieve complete extraction. Replaces manual shaking, reducing the physical strain on laboratory personnel, and avoids direct contact with toxic reagents, protecting the health of the operators. The entire extraction process does not require manual venting; it can automatically discharge through a liquid-liquid extraction instrument and is automatically cleaned. Additionally, the automatic liquid-liquid extraction device significantly reduces environmental pollution, enhances extraction efficiency, and ensures stable and reliable analytical results. Widely applicable to all liquid-liquid extraction tasks, including oils in water, volatile phenols, anions, and more.
Key Features of the Fully Automatic Liquid-Liquid Extraction Instrument:
(1) Auto-extraction, auto-cleaning, auto-waste disposal;
(2) Creatively utilizes the principle of closed-airflow internal circulation oscillation, the extraction process does not require manual venting.
(3) One-touch extraction and oscillation, automatic sedimentation and stratification.
(4) Automatic detergent suction, automatic washing and cleaning.
(5) Automatic discharge of waste liquid, followed by automatic filtering and adsorption treatment by a liquid-liquid extraction instrument and activated carbon storage tank.
(6) Extract multiple sample groups in one go with high efficiency and simple, convenient operation.
(7) Large LCD touch screen design for visual operation

Fully Automatic Liquid-Liquid Extraction Apparatus CH-CQ-6A, Manual Sample Injection, 6-Position Operating SystemKey Features:

1. 7-inch large LCD touch screen, one-touch operation system, the display is fixed in front of the machine for easy operation by experimenters, allowing for independent setting of various instrument parameters.

2. Supports extraction bottles in various specifications; all gas valves are made of PTFE material.

3. 6-position operating system, capable of independently extracting 6 sets of samples; one-touch extraction and oscillation, automatic sedimentation and stratification, each sample can be controlled individually.

4. Extraction time, extraction rate, intermittent time, and extraction cycle can be independently set and adjusted. It comes with an alarm reminder feature.

5. Automatic extraction, degassing, collection, liquid discharge, and cleaning functions.

6. Equipped with a stainless steel telescopic waste liquid tank, suitable for various reagent requirements, featuring an automatic filtration system; no manual draining needed.

7. Features built-in waste liquid activated carbon filtration and purification, reducing environmental pollution.

8. The automatic cleaning function uses a fixed-pressure scatter-type wide-angle cleaning, covering the entire inner wall of the separatory funnel, ensuring more reliable cleaning results.

9. The unit features electric leakage protection, over-voltage and over-current protection devices, and is equipped with 6 independent voltage stabilization systems, enhancing the consistency of the machine's extraction efficiency.

10. Extraction power can be adjusted at will via the knob.

11. Features a bracket with different-sized extraction bottle holders, featuring a snap-on design for easy and convenient replacement.

12. Machines are operable remotely via mobile app, with SMS alert features (upgradable)

Liquid-Liquid Extraction Unit Maintenance and Care

Properly use and maintain the equipment to keep it in good working condition, which can extend its service life.
2. During normal operation, the instrument maintains a stable center of gravity with minimal noise. If abnormal noise is detected, the machine should be shut down to check if any fasteners are loose.
3. During continuous operation, the instrument should be inspected quarterly: check for any water droplets or debris adhering to the instrument components. If found, they should be cleaned promptly.
4. Natural wear and tear is a normal phenomenon after long-term use of the instrument. If abnormal noises or unresponsive components are detected after one to two years of use, it should be repaired promptly.
5. If you feel a tingling sensation or notice unusual sounds, pungent odors, smoking, or other abnormal phenomena while using the instrument, please immediately shut off the power and discontinue use, and promptly contact customer support.
6. Regularly check that power cord plugs and outlets are making good, reliable contact, and that grounding is proper with no overheating.
7. Instruments do not have waterproof features. It is strictly prohibited to expose the instrument to water, as this may cause poor insulation, leading to leakage and malfunctions. In the event of special circumstances where water enters the instrument, immediately disconnect the power and stop using it, and promptly contact customer service.
8. Instruments should avoid excessive humidity to minimize the chance of rust on metal parts.
9. The instrument is only partially corrosion-resistant externally. If strong acids, alkalis, organic solvents, or other reagents splash onto the instrument surface, please immediately shut off the power and stop using it, and wipe it clean promptly; if a large amount of reagent spills into the interior of the instrument, please immediately shut off the power and stop using it, and contact customer service promptly.

Fully Automatic Liquid-Liquid Extraction Apparatus CH-CQ-6A, Manual Sample Injection, 6-Station Operating SystemTechnical Specifications:

1. Extraction function

(1) Time Setting: 0-999s; (2) Extraction Times: 0-99 times; (3) Extraction Interval: 0-999 seconds;

(4) Extraction Intensity: adjustable from mild to strong; (5) Layering Method: automatic extraction program operation, automatic settling and layering, manual liquid release.

2. Cleaning Function

(1) Time Setting: 0-999s; (2) Washing Cycles: 0-99 times;

(3) Cleaning interval: 0-999 seconds; (4) Cleaning method: Press-scattered wide-angle cleaning

3. Sample Addition: Manual Sample Addition (optional auto-sampling available)

4. Waste Liquid Treatment: Waste liquids are filtered and adsorbed through an activated carbon storage tank before being collected and processed centrally, suitable for extraction experiments with various samples.

5. Exhaust Treatment: Automatic exhaust release; the exhaust is filtered and adsorbed in the storage tank before being collected and treated centrally.

6. Display Method: 7-inch Large LCD Touch Screen

7. Sample Quantity: 6 pieces, including 6 standard 250ml, 500ml, 1000ml, or 2000ml extraction bottles (standard 1000ml)

8. Power Voltage: 220V ± 22V, 50Hz

9. Rated Power: 400W


询价单

主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》