High-speed centrifuges are used in fields such as (Disease Control Centers, Animal Husbandry and Aquaculture, Radioimmunoassay); research (Universities, Research Institutes, R&D Centers, Laboratories); and production (Biological Engineering, Bio-manufacturing, Genetic Engineering, Biochemistry, Plant Extraction, Food Processing, Petrochemicals, Dairy Separation).


Key Features:

Microcomputer control, touch screen panel, intuitive digital display, operating parameters can be automatically memorized for easy operation and use.

2. Brushless motor drive, imported super high-speed bearings, smooth operation, maintenance-free, multi-layer vibration reduction structure, low vibration, low noise, environmentally friendly

3. Steel body, stainless steel centrifugal chamber, key components imported, easy to clean, durable

4. Over-temperature, over-speed, door cover, unbalanced protection, etc., ensure safety; dual protection with electronic lock and mechanical lock

5. Airflow guiding design with minimal temperature rise, effectively protecting the samples. Ten adjustable ascending and descending speeds, customizable centrifugal parameters for optimized centrifugation.


Technical Specifications:

Model TG20G, Timing Range: 0-99min

Speed ≤ 20,500 rpm, Power Supply AC 220V 50Hz 18A

Relative centrifugal force ≤ 29,800×g; Overall noise ≤ 60 dB

Capacity ≤ 600ml, Dimensions: 570*400*330mm

Speed ±50r/min, Weight 65kg


Rotor Type Rotor Number Capacity (ml) Rotor Speed (r/min) Relative Centrifugal Force (xg)

Corner turner 1, 12×1.5ml, 20500, 29800

2 18×0.5ml 20500 29800

3 24×1.5/2.0ml 16000 23200

4 48×0.5ml 13000 14740

5 10×5/7ml 16000 17420

6 12×10ml 15000 23120

7 6×50ml 13000 17380

8 12×15ml 10000 10290

9 4×100ml 10000 9690

10 8×50ml 10000 9690

11 6×100ml 8000 8450

Horizontal Rotor 12 2x48 Holes 3000 1400


Centrifuge Operation Guidelines

  1. The centrifuge lid must be closed when the centrifuge is in pre-cooling mode. After the centrifugation is complete, remove the rotor and place it upside down on the lab table, wipe dry any remaining water inside, and leave the centrifuge lid open.
    2. When pre-cooling, the head cap can be placed on the centrifuge platform or on the lab table. Absolutely do not leave it loosely on top of the head, as if mistakenly activated, the head cap could be propelled out, resulting in an accident!
    3. After tightening, always use your fingers to check for gaps between the turning head and the turning cover. If there are gaps, loosen and retighten until no gaps are confirmed, then you can start the centrifuge.
    4. During the centrifugation process, operators must not leave the centrifuge room. In case of an abnormal situation, operators cannot shut off the power (POWER); they must press STOP. The centrifuge usage record must be completed before pre-cooling.
    5. Do not use counterfeit centrifugal tubes, and do not use aged, deformed, or cracked centrifugal tubes.
    6. Must leave after the centrifuge routine safety check is performed on the next working day following holidays and evenings.
    7. In case of machinery failure or component damage during the instrument's use, please contact us promptly.