详情描述

Carbon Dioxide Incubator HH.CHP-T

A CO2 incubator is an experimental instrument used for culturing cells, tissues, and bacteria. It is applied in the research and production of microbiology, agricultural science, and pharmacology.

 

Key Features:

1. The CO2 incubator features a streamlined curved design, with the outer shell made of cold-rolled steel plate and electrostatic powder coating. The inner lining is constructed from stainless steel material, and the semi-circular corner design facilitates easy cleaning.

2. Microcomputer temperature controller with minimal temperature fluctuations; equipped with an ultraviolet sterilization lamp inside the box for regular UV disinfection, preventing contamination during cell culture.

3. Double-door structure: After the outer door is opened, observe the laboratory conditions inside through an inner door made of high-strength tempered glass, with no impact on temperature and humidity.

4. The CO2 concentration sensor is equipped with a genuine Finnish-made ir infrared probe, allowing for direct display of the CO2 concentration inside the box, and operates reliably.

5. An independently set door heating system effectively prevents condensation on the inner door glass.

6. The studio utilizes a water tray for natural evaporation humidification, with humidity displayed directly by the gauge.

7. The carbon dioxide incubator is equipped with an independent temperature alarm system that automatically shuts off if the temperature exceeds the limit, ensuring safe operation of the experiment and preventing any accidents.

 

Carbon Dioxide Incubator HH.CHP-T

Technical Specifications

Model

HH.CHP-T

HH.CHP-01

HH.CHP-TW

HH.CHP-01W

Volume

80L

160L

80L

160L

Heating Method

Gas jacket

Water jacket

Temperature Control Range

Room temperature +5~65℃

Temperature Resolution

0.1℃

Constant Temperature Fluctuation

±0.2℃

CO2 control range

0~20%

CO2 control method

Infrared Microcomputer CO2 Concentration Probe Controller

Humidification Method

Natural Evaporation (Water Tray)

Humidity Range

Greater than 95% RH (+37°C operating temperature)

Office Hours

1 to 9999 minutes or continuous

Power

400W

500W

850W

1250W

Work power supply

AC 220V 50Hz

Studio size

400*400*500

500*500*650

400*400*500

500*500*650

Dimensions

550*610*785

650*710*935

550*610*775

650*710*925

 

CO2 Incubator Usage Precautions

Do not turn on the power switch before filling the CO2 incubator with water; otherwise, it may damage the heating element.

2. Replace the cylinder when the pressure is below 0.2 MPa.

3. The CO2 incubator can be used as a high-precision constant temperature incubator, at which point the CO2 control system must be turned off.

4. Since the CO2 sensor is calibrated under saturated humidity, the humidifying disk must always be filled with sterilized water.

5. After the incubator has been running for several months, the water in the tank may decrease due to evaporation. When the low water level indicator (WLow12) illuminates, add water as needed. First, open the overflow pipe, and use a funnel to connect a rubber hose from the filling hole to replenish water until the low water level indicator turns off. Then, measure and add the necessary water, and finally, seal the overflow hole.

6. When the displayed temperature exceeds the set temperature by 1°C, the OverTemp7 indicator light illuminates and emits a sharp alarm sound. At this point, the power should be turned off for 30 minutes; if the temperature remains above the limit even after the Power20 (temperature control) switch is turned back on, the power should be shut off and a maintenance crew should be notified.

Do not碰撞sensors and impeller blades of the stirrer motor and other components when cleaning the clean CO2 incubator workroom.

8. Minimize the time spent opening glass doors.

9. If the CO2 incubator is not used for an extended period, it must be drained of moisture in the chamber before turning off. Open the glass door for ventilation for 24 hours before closing it.

10. When removing or installing the protective guard of the indoor bracket in the disassembly workshop, it is mandatory to use the included special wrench; do not apply excessive force.

11. Before moving the CO2 incubator, remove the shelves and humidifying trays from the laboratory to prevent damage to the glass door upon collision.

Before moving the incubator, water inside must be drained. When draining, tightly fit a rubber tube over the drain hole, ensuring the tube's opening is below the instrument. Take a gentle suck, then release the water pipe, and the water will flow out.

Do not invert the incubator when handling, and be sure not to lift the incubator door to prevent deformation.


询价单

主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  