Shanghai Youke Instrumentation Co., Ltd.VIP

国产通用分析仪器专业制造商-致力于实验室通用分析仪器
Enter Shop

GC-7866 Networked Series Gas Chromatograph

平台认证
  • Unit Price

    Negotiable

  • Brand

    YuKe Instruments

  • MOQ

Contact
Leave Msg

Platform Service

Supplier Verified



上海佑科仪器仪表有限公司

VIP   标王第2年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    YuKe Instruments

  • Unit Price:

    Negotiable

  • MOQ:

  • Total:

    0Piece

  • Address:

    Shanghai

  • Delivery:

    0Hours

  • View More

Description

Product Specifications

Product Details

The GC-7866 series networked gas chromatograph is a new type of digital, fully controlled gas chromatograph newly launched by Shanghai Youke Instrument Co., Ltd. The instrument has fully absorbed advanced technology from similar foreign products and employs the most advanced manufacturing technology and processes in the domestic industry, ensuring the reliability and operating time of the instrument. It not only extends the normal operating time and reduces the frequency of maintenance but also features a more concise and rational structure and a more majestic appearance; its intuitive keyboard operation and convenient reverse control software make it easy to learn and operate.

1. Technical Specifications

(1) Controllable for all temperature settings on the chromatography main unit, program-controlled temperature ramping, sensitivity switching, and collection of chromatography output signals; equipped with

Program升温curve tracking features; Achieve a single communication line connection to an external computer for real-time instrument control and data processing.

Please provide the Chinese content to be translated.

(2) Reverse control software supports the automatic calculation and display of preset method data results: method establishment includes instrument parameters and standard curves.

Wires, prior to sampling, select the established method. Once the sampling is automatically completed, the reverse control software can perform automatic calculation of the results.

Automatic display function.

(3) Equipped with an 8.0-inch liquid crystal capacitive touch screen, the same interface displays the sampler, column oven, detector, as well as auxiliary temperature settings and real-time temperature readings.

(4) Features at least 6 independent temperature control zones with extreme temperature and over-temperature protection.

(5) Full Chinese keyboard setup for various control and usage parameters (including detector operation parameters).

(6) Features include self-diagnosis, power failure protection, detector settings, range, polarity, and current settings with display.

(7) The column cabinet features rapid heating and cooling with an automatic back door structure (capable of cooling from 300°C to 50°C within 10 minutes), and can be adjusted according to

Automatically adjusts door opening angle with temperature changes.

(8) High-precision dual stability air circuit, the following are the sealing requirements for each air circuit system:

Gas Carrying Pipeline System Sealing: InHydrogen GasAt 0.2 MPa pressure, the pressure drop ≤ 0.01 MPa within 0.5 hours.

Gas pipeline system tightness: EnsuringHydrogen GasAt 0.2 MPa pressure, the pressure drop within 0.5 hours ≤ 0.02 MPa.

Assisted gas supply system sealability: Pressure drop ≤ 0.01 MPa within 0.5 hours under 0.2 MPa air pressure.

(9) Column Temperature Range: 7°C above room temperature to 400°C (in increments of 1°C)

(10) Temperature Control Objects: Column Oven, Front and Rear Detectors, Front and Rear Sample Pumps, Auxiliary, Total of 6 Channels

(11) Step-up Ranges: 23-step step-up, step-up rate not less than: 0.1℃~40℃/min (increment of 0.1℃)

(12) Temperature Stability: ≤0.5%

(13) Programmed Temperature Repetition: ≤1%

(14) TCD (Thermal Conductivity Detector) Sensitivity: Not less than 5000 mV•mL/mg; Baseline Noise: ≤20 µV; Thermal Conductivity

Detector (TCD) Baseline Drift: ≤60µV/30min

(15) The software complies with the national standard "GB/T25478-2010 Chromatography Data Workstation."

(16) Standardized, open data interfaces that allow for importing and exporting spectrum data, methods, and analysis results, etc., in compliance with

ASTM/AIA standard CDF files, with support for data interfaces with fingerprint spectrum software

(17) The software supports the use of full reverse control automatic samplers and features open ports for future upgrades to full reverse control samplers.

 

Two: GC-7860 Network Version Anti-Control Workstation:

Features and Functions:

  1. *Communication Methods: Network-based communication, IEEE802.3 Ethernet interface; workstations also support RS232 communication interface.
  2. The integration of chromatography data processing and instrument reverse control operations ensures easy operation and a user-friendly interface.
  3. ▲Workstation software allows for the setting and control of parameters such as the temperature of the heating zone, user-defined names for the heating zone, enable switches, gas flow and pressure, program voltage control, program heating and external events, automatic sampler, multi-channel sample selection control, and detectors.
  4. ▲Workstations support multi-channel data processing for multiple chromatographs, designed to accommodate connections for up to 5,000 chromatographs. Each chromatograph's data processing supports four-channel signal handling, with the fourth channel being a virtual channel for convenient display of multiple detector signals on a single spectrum and featuring a straight baseline function.
  5. The workbench software features an integral time program setting with practical functions such as baseline locking, negative peak identification, and negative peak inversion.
  6. Data analysis results can be converted into Word format for easy printing, output, and copying.
  7. Automatically generates folders named by chromatograph models and timestamps, facilitating simultaneous management of multiple chromatographs for users.
  8. The 7866NetChorm Network Edition Anti-Control Workstation can remotely transmit analysis results to where the user needs them via various transmission methods (Internet, CAN Bus, MODBUS Bus, GPRS Communication, 3G Communication, Wireless Special Networks, etc.).
  9. Data analysis can conveniently upload to the DCS system, featuring a 4mA to 20mA output for easy industrial online closed-loop control.
  10. Utilizing multithreading technology to enable simultaneous coordination of signal collection, data processing, and user management.
  11. Software architecture supports rich configuration for multiple monitoring seats within a single system; each spectrometer supports simultaneous access from three IP addresses.
  12. Equipped with an extended communication interface for analysis results, supporting user secondary development and feature expansion.
  13. PeakSmart Intelligent Recognition Technology, reduces the number of spectrum processing parameters that need to be set by users, and basically achieves automatic processing of peak detection, baseline correction, and overlapping peak segmentation.
  14. The CDF files compliant with A/A (American Analytical Society) standards can be read for sampling data, thereby interfacing with chromatography workstations such as Agilent and Waters.
  15. Utilizing high-fidelity digital filtering algorithms, it boasts robust noise immunity, capable of detecting weak peaks on par with baseline noise.
  16. Data processing includes: normalization, corrected normalization, single-point correction (single-point internal standard method, single-point external standard method), and multi-point correction (multi-point internal standard method, multi-point external standard method).
  17. The 7866NetChorm Network Edition Workstation can also be equipped with a "Component Content Monitoring System," which completes the statistics, analysis, and monitoring of chromatographic component content. It is suitable for chemical product production (such as reactions,分流, distillation, etc.) to conduct data statistics, content trend analysis, threshold detection, and threshold alarms for various components of samples. This makes the trend of component content changes clear at a glance. Data from the day or shift are automatically archived, eliminating the need for manual spectrum analysis, manual spectrum organization, and manual result judgment, thereby improving the factory's level of automation.

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery Shanghai
Brand YuKe Instruments
Contact Person Mr. Meng
Phone 186-0176-7928
Brand YuKe Instruments
Expiry Long Valid
Update 2025-12-10 14:16
Gallery

Shanghai Youke Instrumentation Co., Ltd.Published byGC-7866 Networked Series Gas ChromatographGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top