Shandong Zhongjie Special Equipment Co., Ltd.VIP

中杰特装储罐主营:LNG储罐、LPG储罐、液氧储罐、化工设备等安装服务.
Enter Shop

Hainan Carbon Dioxide Storage Tank - On-Site Installation

平台认证
  • Unit Price

    $10000.00/Tai

  • Brand

    Zhongjie

  • MOQ

    1Tai

Contact
Leave Msg

Platform Service

Supplier Verified



山东中杰特种装备股份有限公司

VIP   数字营销第2年
资料通过中商114认证
  • Shandong
  • 于秋波 (Mr.)   业务经理
Category
  • No Category

Product Details

Specs

Gallery

  • Brand:

    Zhongjie

  • Unit Price:

    $10000.00 / Tai

  • MOQ:

    MOQ1Tai

  • Total:

    9999Tai

  • Address:

    Shandong

  • Delivery:

    3days

  • View More

Description

Shandong Zhongjie Special Equipment (formerly Heze Boiler Factory Co., Ltd.) holds an A-grade boiler manufacturing license, A2-grade pressure vessel manufacturing license, A2-grade pressure vessel design license, B-grade boiler installation, and GB2/Class, GC2/Class pressure pipeline installation licenses, as well as a mechanical and electrical equipment installation contracting qualification. It is a member of the China Boilers and Water Treatment Association, the China Chemical Equipment Association, and the council member of the Shandong Equipment Manufacturing Association. The company has also passed certifications for the ISO9001 Quality Management System, ISO14001 Environmental Management System, OHSAS18001 Occupational Health and Safety Management System, and the U.S. ASME/U2 certification.
The application standards for liquid carbon dioxide storage tanks primarily include the following aspects:
海南二氧化碳储罐
Common defects in carbon dioxide storage tanks during use may include deformation. Here are some reasons that may cause tank deformation: Overpressure: When the internal pressure of the tank exceeds its design pressure, it may lead to deformation. This could be due to operational errors, system failures, or other causes. Temperature Changes: Carbon dioxide storage tanks undergo thermal expansion and contraction under temperature variations. If the temperature changes are too extreme or rapid, it may result in tank deformation. Internal Corrosion: If there is internal corrosion in the tank, it can damage the structural integrity of the tank, leading to deformation. External Damage: External impacts, compressions, or other physical damages may cause tank deformation. Incorrect Installation or Use: Incorrect installation or usage methods may lead to uneven stress on the tank, causing deformation. Tank deformation may reduce the structural integrity of the tank and even pose risks of leakage or rupture. Therefore, it is important to regularly inspect and maintain the integrity of the tank, as well as to follow proper operational and installation procedures. If tank deformation or other defects are detected, the tank should be immediately stopped from use and professional assistance should be sought for inspection and repair. Do not attempt to repair or continue using a defective tank to ensure operational safety.
海南二氧化碳储罐
The testing and maintenance of liquid oxygen storage tanks are crucial for ensuring safe operation and extending their lifespan. Below is a general outline of the testing and maintenance procedures for liquid oxygen storage tanks: - Visual Inspection: Regularly inspect the exterior of the liquid oxygen storage tank for corrosion, wear, and cracks. Promptly repair or replace any abnormalities found. - Internal Cleaning: Regularly clean the interior of the liquid oxygen storage tank to remove accumulated impurities and dirt. Use appropriate cleaning agents and tools to avoid damaging the tank. - Level Measurement: Regularly measure the level to ensure the liquid oxygen storage tank's level is within a safe range. Use level gauges or other measuring equipment and record the results. - Pressure Testing: Regularly conduct pressure tests to verify the tank's pressure resistance. Control pressure and time during testing to ensure safety and accuracy. - Leak Detection: Regularly perform leak detection to ensure the tank's sealing integrity. Use leak detection equipment such as gas detectors or foam leak detectors. - Valve and Pipe Inspection: Regularly check the valves and pipe connections of the liquid oxygen storage tank to ensure proper sealing and no leakage. Promptly repair or replace any issues found. - Maintenance Records: Keep records of the testing and maintenance activities, including dates, inspection content, and results. These records help track the tank's maintenance history and issue resolution. - Scheduled Maintenance: Develop a regular maintenance plan based on the tank's usage and requirements. Maintenance includes lubrication, bolting, and replacing seals to ensure smooth operation.
海南二氧化碳储罐
Key measures to ensure the quality of CO2 storage tanks include the following aspects: 1. Selecting qualified suppliers: Choose suppliers with a good reputation and experience, ensuring that the tanks they provide meet relevant quality standards and specifications. This can be achieved by evaluating the supplier's qualifications, referencing customer reviews, and conducting on-site inspections to select suitable suppliers. 2. Strict quality control: Implement rigorous quality control measures during the manufacturing process of the tanks. This includes selecting and inspecting raw materials, controlling production processes, monitoring process parameters, and conducting product testing and inspections to ensure the tanks meet quality requirements. 3. Compliance with standards and regulations: The design, manufacturing, and installation of the tanks should comply with relevant standards and specifications, such as industry standards and regulations. These include the structural design of the tank, material selection, welding processes, corrosion prevention measures, and the configuration of safety valves and pressure sensors. 4. Regular inspections and maintenance: Tanks should undergo regular inspections and maintenance during use to ensure safety and reliability. This involves checking the tank's appearance, sealing, valves, and pipeline connections, conducting regular pressure tests and leak detection, and promptly addressing any anomalies. 5. Establishing a quality management system: Develop a comprehensive quality management system, including quality control processes, documentation, quality training, and internal audits. By establishing a quality management system, tank quality control and continuous improvement can be ensured. 6. Third-party testing and certification: Delegate tank testing and certification to third-party agencies to verify quality and compliance. Third-party testing and certification bodies are typically independent and objective, providing objective assessment and certification results. 7. Through the implementation of these measures, the quality of CO2 storage tanks can be effectively ensured, enhancing their safety and reliability.
Our company attaches great importance to technological innovation and R&D design. We have 1 municipal-level enterprise technology center in Heze City, equipped with testing facilities for non-destructive testing, physical and chemical testing, welding testing, hydrostatic testing, etc. We have over 600 pieces of various equipment such as CNC machine tools, X-ray flaw detectors, digital ultrasonic flaw detectors, mechanical property testing machines, chemical analyzers, spectrometers, tensile testing machines, plasma welding machines, and more. The key products we have developed, such as temperature-pressure vessel welding, biomass boiler emission reduction, and waste heat recovery, have successively been included in multiple Shandong Provincial Department of Industry and Information Technology science and technology projects, Shandong Provincial key projects, and Heze City innovation and excellence projects. We have accumulated 27 authorized utility models, 16 authorized inventions, participated in drafting 2 standards, 2 industry standards, and registered 15 trademarks. Our technical team, in collaboration with Professor Yajiang Li of Shandong University, has jointly developed deep cryogenic vessel processing technology using the international plasma arc + filler wire argon arc welding (PAW-GTAW) technology, which has reached international standards after provincial-level scientific and technological achievement appraisal. Choose Zhongjie Special Equipment, let's join hands to create brilliance!

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $10000.00 / Tai
Sales None
Delivery Shandong3dayswithin
Stock 9999TaiMOQ1Tai
Brand Zhongjie
Form Vertical
Pressure 2.16
Type Carbon Dioxide Storage Tank
Expiry Long Valid
Update 2025-06-23 08:55
Gallery

Shandong Zhongjie Special Equipment Co., Ltd.Published byHainan Carbon Dioxide Storage Tank - On-Site InstallationGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top