Shielded Room
I. Usage
Primarily used for electromagnetic shielding in electronic devices, high-frequency medical equipment protection, communication equipment maintenance, and metrological testing sites.
Section II: Features
Design of electromagnetic shielding rooms can be tailored to the specific shape characteristics of buildings, meeting the electromagnetic shielding requirements for various geometrically sized rooms, conference rooms, machine rooms, and other locations that require electromagnetic shielding. Easy to install, cost-effective, and commonly used in the market.Please provide the Chinese content that needs to be translated into American English.Standard GJBZ20219-94Please provide the Chinese content you would like translated into American English.General technical requirements and testing methods for electromagnetic shielding rooms, B-grade standard requirements. Performance indicators:

The testing methods for steel plate direct bonding shielding rooms are conducted according to the national standard GB12190-2006.
Section 3: Structural Composition
1. The shielding layer is installed directly on the wall or onto a straight-type steel frame using galvanized steel plate or metal wire mesh with a thickness of 0.35 to 1mm.
2. The door features a decorative screen door for aesthetic appeal.
3. The windows are equipped with shielded glass that allows for natural light, and they open easily.
4. Ventilation Waveguide Windows: Honeycomb ventilation waveguide windows, size 300×300mm. Available for connection with central air conditioning or fresh air systems, custom-sized waveguide windows can be configured according to shielded room specifications.
5. High-performance low-leakage power filter: Capable of handling various specifications of 220V/380V, 50Hz power cables, suitable for use with shielded room equipment.
6. Indoor Electrical: Indoor electrical system includes distribution boxes, recessed fluorescent lighting (testing rooms can only use incandescent bulbs, the quantity depends on the function and calculated illuminance), cable routing, control switches, and outlets (wall-mounted, floor-mounted, or socket box, quantity determined by customer requirements).
7. Interior Decoration: Decorate the ceiling, walls, and floor according to customer specifications.
8. Other: Air conditioning can be installed in the shielding room upon customer request, and signal processing can be conducted. Additionally, all cables entering and exiting the server room must be shielded (such as telephone, fire alarm, surveillance, fiber optic, and various data lines).
For details, please contact: 020-82325801, 82323025.