Product Description


Brand  Hegu Group  Model  CFW-100/0.8

Material: Stainless Steel, Diameter: 3400mm

Application Range: -162℃; Volume: 100,000L

Heat Exchange Area - See drawing sq. m Ambient Temperature - See drawing °C

Wall Thickness: 10/12mm, Dimensions: 3424*16442mm

Origin: Shandong Heze

    


60 Cubic Meters LNG Tank Price | Supplier of 30 Cubic Meter and 60 Cubic Meter LNG Tanks


3. LNG Storage Tank Fault Inspection and Handling 3.1. Daily Inspection


3.1.1 Level gauge and pressure gauge operation check.


3.1.2 Are the shut-off valves, regulating valves, and safety valves in normal working condition?


3.1.3 Check for leaks in tanks, pipelines, and valves.


3.2 Regular Inspections


3.2.1 The pressure gauge should be calibrated annually and accompanied by a certificate of inspection with a lead seal.


3.2.2   The safety valve should be calibrated annually and sealed with lead.


3.2.3 Low-temperature liquids should be analyzed every three to six months as needed for operations.


3.3 Fault Handling


Fault occurred


Original Cause


Mitigation Measures


1. Abnormal inner tube pressure


Increase or Decrease


A Pressure Gauge Distortion


B tank vacuum reduced


Valve operation error


A pressure gauge


B Weight Vacuum Packed


C conforms to the manual's operation requirements.


2 Level Gauge Distortion


Improper operation of the A level gauge valve


The B level gauge is damaged.


Reoperate as per requirements.


B Replace with new level gauge


3 External frosting on storage tank


Vacuum Failure


B-laminate leakage


C iridescent sand settling down


A vacuum again


B pressure test and leak detection, then evacuate the air


C Balance Insertion of Pearlite Sand and Re-vacuuming


Note:


1. If the user needs to evacuate or refill the pearl sand in the sandwich, it is necessary to first empty the inner cylinder liquid and wait until the inner cylinder returns to room temperature before proceeding.


2. If users encounter issues that are difficult to handle, they may contact our after-sales service department promptly. Our company offers a three-package quality guarantee for our products. We also provide repair services for products beyond the warranty period and those not from our company.


4. Cautionary Notes


4.1 The vacuum valve is sealed before the product leaves the factory. After the storage tank is delivered to the customer's site, the customer must ensure the protection of all pipeline valves during installation, especially the vacuum valve, and strictly prohibit any collision or opening of the vacuum valve.


4.2   Do not empty the liquid in the storage tank unless it will be unused for an extended period, to prevent the inner cylinder from heating up, which could require re-cooling when refilling and result in unnecessary losses.


4.3 Low-temperature liquid storage tanks are used for storing liquid nitrogen, liquid oxygen, and liquid argon. However, when switching to another liquid, the original liquid must be completely emptied and purged before refilling with the new liquid.


Note:


1. The fill valve opens when the liquid is almost full, closes when liquid starts to flow, and stops the liquid intake. When filling for the first time, start from the top and then from the bottom.


2. Open during waste liquid discharge.


3. Release the vent valve when the container pressure is too high.


4. The container automatically opens when over-pressurized. Normally, only one is in use. If the operating one fails, the other is immediately activated to ensure the safe operation of the storage tank. The damaged safety valve is then repaired and inspected, and upon passing the inspection, it is promptly reinstalled.


5. The inner cylinder automatically starts after the pressure-increasing valve is opened when it requires pressure increase.


6. The level gauge is often turned off during normal operation.


7. Blast upon overpressure; immediate replacement required after blast.


 









 

Natural Gas Storage Tank Price - Factory Direct 100 Cubic Horizontal LNG Tank, Competitive Pricing - High Vacuum Level


Product Description


Brand Hegu Group Model CFW-30/0.8

Material: Stainless Steel, Diameter: 2916mm

Application Range    -162℃    Volume    30000L

Heat Exchange Area - See drawing m², Ambient Temperature - See drawing °C

Wall Thickness: 8/10mm, External Dimensions: 2916*8289mm

Origin: Shandong Heze

30立方立式lng储罐 卧式LNG储罐 低温天然气储罐厂家


The low-temperature storage tank is double-walled, with the inner tank containing low-temperature liquids, withstands pressure and low temperatures from the medium, and is made of cryogenic-resistant alloy steel (0Crl8Ni9). The outer shell acts as a protective layer for the inner tank, maintaining a certain distance to create an insulating space, supporting the gravitational loads of the inner tank and medium, as well as the vacuum negative pressure of the insulating layer. The outer shell does not come into contact with the low temperature and is made of container steel. The insulating layer is mostly filled with mica sand and a high vacuum is drawn. The evaporation rate of the low-temperature storage tank is generally below 0.2%.


LNG tanks are categorized by capacity


(1) Small (5~50 m3): Commonly used at civil LNG refueling stations and civil gas liquefaction stations, etc. (2) Medium (50~100 m3): Often employed at industrial gas liquefaction stations. (3) Large (100~1000 m3): Suitable for small-scale LNG production facilities.


(4) Large (10,000-40,000 m³): Used for base load and peak-shaving liquefaction units. (5) Extra-large (40,000-200,000 m³): Used for LNG receiving stations.


LNG storage tanks are categorized by shape.


Spherical: Generally used for medium to small capacity storage tanks. (2) Cylindrical: Used in storage tanks of various capacities. LNG storage tanks are categorized by their placement: (1) Above ground: Located on the ground. (2) Underground: Located beneath the ground.


Determination of Design Pressure and Calculated Pressure


Currently, the majority of 100m3 vertical LNG storage tanks have a maximum working pressure of 0.8MPa. According to the regulations of GB150 "Steel Pressure Vessels," when the maximum working pressure of the tank is 0.8MPa, the design pressure can be taken as 0.84MPa. The filling factor of the tank is 0.95, and the net pressure of the liquid column in the inner tank after filling with LNG is 0.062MPa. The absolute pressure between the inner and outer tanks is 5Pa, resulting in a calculated pressure of 1.01MPa for the inner tank.


The primary function of the outer tank is to fix the inner tank and the insulating material in a suspended or supported manner, forming a high-vacuum insulating layer with the inner tank. The loads acting on the outer tank are mainly the gravitational loads of the inner tank and the medium, as well as the vacuum negative pressure of the insulating layer. Therefore, the outer tank is an external pressure vessel, with a design pressure of -0.1 MPa.


Material selection for LNG tanks


During normal operation, the working temperature of the LNG storage tank is -162.3°C. Before the first use, the tank must be pre-cooled using liquid nitrogen at -196°C, so the design temperature of the tank is -196°C. The inner tank must withstand both the working pressure of the medium and the low temperature of LNG, requiring the inner tank material to have excellent comprehensive mechanical properties at low temperatures, particularly good low-temperature toughness. Therefore, the inner tank material is selected as SS30408. Based on the calculated pressure of the inner tank and the selected material, the calculated thickness and design thickness are 11.1mm and 12.0mm, respectively. As a normal temperature external pressure vessel, the outer tank material is chosen as low-alloy steel 16MnR, with a design thickness of 10.0mm.


LNG Tank接管Design


Tapped openings on the inner tank include: inlet liquid, outlet liquid, liquid discharge, vapor phase, level measurement, upper level gauge, lower level gauge, and 8 process manholes. All tapped openings on the inner tank are made of OCrl8Ni9 material.


To facilitate regular measurement of vacuum levels and evacuation, a vacuum evacuation port is provided in the lower封头 of the outer tank (the port is sealed after evacuation). To prevent vacuum failure and the leakage of the inner tank medium into the outer tank, a pressure relief device is installed in the封头 of the outer tank.




 

30立方立式lng储罐 卧式LNG储罐 低温天然气储罐厂家





知名液化天然气储罐公司-专业制造液化天然气储罐制造商-菏泽锅炉液化天然气储罐燃气蒸汽锅炉-专业液化天然气储罐厂家

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $1.00 / Tai
Sales None
Delivery Shandong3dayswithin
Stock 9999TaiMOQ1Tai
Brand Zhong Jie
Inventory Quantity 9999
Working Voltage 380v
Effective Water Volume For detailed inquiries
Expiry Long Valid
Update 2025-05-29 08:47
Gallery

Shandong Zhongjie Special Equipment Co., Ltd.Published byProfessional Liquefied Natural Gas Tank Contact PhoneGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top