Shenzhen Zhongnuo Testing Technology Co., Ltd. specializes in the certification, calibration, and metrological services for gas alarms, combustible gas detectors, toxic and harmful gas detectors, and other equipment in various locations. We are fully qualified to serve nationwide, addressing all types of electrical safety and explosion-proof fire prevention issues for our clients, and contributing to safe production.
Regular Inspection Content for Gas Alarms
Installation spacing of inspection points
2. Installation Height of the Detector
3. Indication Error (Concentration)
4. Repeatability (Concentration)
5. Alarm Error (Concentration)
6. Response Time (Seconds)
Appearance and structure
The instrument should not have any appearance damage that affects its normal operation. The surface of newly manufactured instruments should be smooth and even, with a uniform paint and plating layer, free of peeling and rusting.
The instruments have reliable connections; all dials or buttons should operate and control normally.
Logos and branding elements
Instrument name, model, manufacturer's name, manufacturing date, serial number, explosion-proof marking and number, as well as the manufacturing metrological instrument license marking and number for domestic instruments should be clear.
GB 12358-2024 "General Technical Requirements for Environmental Gas Detection and Alarm Instruments in Workplace" is an important standard.
Intended to standardize the performance, functions, and testing methods of environmental gas detection alarm instruments used in work sites.
The standard was issued in 1990 and has undergone several revisions.
The new version is GB 12358—2024, which will be officially implemented on June 1, 2025.
This standard applies to the production and use of gas detection and alarm instruments for flammable gases, toxic and harmful gases, and oxygen in workplace environments.
The calibration cycle for flammable gas detectors is typically once a year.
In accordance with the standard JJG 693-2011 "Flammable Gas Detector and Alarm," the calibration period for flammable gas alarms generally does not exceed one year. This means that under normal circumstances, a comprehensive calibration and test of the flammable gas alarm should be carried out annually to ensure that its performance meets the relevant requirements.
Shenzhen Zhongnuo Testing Technology Co., Ltd. is a third-party institution specializing in electrical safety, electrical explosion-proofing, gas alarm systems, and toxic and harmful gas alarm instruments. We offer regular certification, measurement, and calibration services, as well as qualifications to help clients address fire and explosion prevention issues.