Anhui Tianming Cable Co., Ltd. --- Wire Armored Cable WDZ-KYJY33 Low Smoke Halogen-Free Flame Retardant Cable, produced in accordance with national standards GB/T18380, GB/T19216, GB/T17651, GB/T17650, and international standards.
Steel Wire Armored Cable WDZ-KYJY33 Low-Smoke Halogen-Free Flame Retardant Cable – This low-smoke halogen-free flame retardant cable is difficult to ignite and has the ability to prevent or inhibit spread. Moreover, once ignited, it features halogen-free, low-smoke, non-toxic, and non-corrosive properties. Suitable for high-rise buildings, hotels, hospitals, subways, nuclear power plants, tunnels, power plants, mines, oil, and chemical industries.
Low-smoke, halogen-free, fire-resistant cables, in addition to meeting the characteristics of low-smoke, halogen-free, flame-retardant cables, also maintain the ability to supply power under fire conditions. They are mainly used in power supply lines for fire alarms, fire-fighting equipment, smoke extraction systems, and emergency exit lighting, among other emergency facilities, where fire resistance is required.
Two, flame-retardant rating and product performance of low-smoke halogen-free cables:
According to the test conditions specified in GB/T18380.3-2002, flame-retardant low-smoke halogen-free cables are classified into four grades: A, B, C, and D.
Wire armored cable WDZ-KYJY33, low smoke halogen-free flame-retardant cable with rated voltage of 600/1000V, cross-linked polyethylene insulation, flame-retardant B-class low smoke halogen-free sheath cable, 3 cores, 240mm².
WDZB-YJY 600/1000V 3*240 Q/TEC16.05-2005
1. Rated voltage U of the control cable. / U is 450/750V.
2. The cable is designed for continuous operation at temperatures not exceeding 90°C.
3. The installation environment temperature should not be below 0℃.
4. Minimum Bend Radius for Cable Installation
Low-smoke, halogen-free, flame-retardant, fire-resistant control cables: The cable without armor layer should not be less than 6 times the cable outer diameter, and the cable with armor or copper tape shielding structure should not be less than 12 times the cable outer diameter.
B、Low-smoke, halogen-free flame-retardant, minimum bend radius for fire-resistant power cables. See the table below: (Outer diameter of cable D)
III. Cable Structure:
Conductor: Bare copper wire or tin-plated copper wire, solid-core, multi-core braided, or fine strands twisted into bundles, compliant with GB/T 3956 and IEC 60228 *** class (Class A), Category 2 (Class B), or Category 5 (soft structure).
Insulation: Polyethylene (PE), Cross-linked Polyethylene (XLPE).
Armored sheath: Double steel strip or galvanized steel wire armor, galvanized steel wire braid armor, or copper wire braid armor (the braid density of the layer is not less than 65%).
Shielding Layer: Braided bare copper wire or tin-plated copper wire, wrapped with copper-plastic or aluminum-plastic composite tape, or a combination of braided copper wire with aluminum-plastic composite tape shielding.
Housing: Low smoke zero halogen flame-retardant polyolefin.
Core Wire Identification: Color marking or white numbering printed on black core wire.
Four, Product Model:
| Low-smoke, halogen-free, flame-retardant control cable | |||
| WDZ-KYJY | Copper-core cross-linked poly-insulated halogen-free low-smoke flame-retardant control cable | ||
| WDZ-KYJYP | Copper-core Cross-linked Insulated, Copper-wire Shielded, Halogen-free, Low-smoke Flame-retardant Control Cable | ||
| WDZ-KYJYP2 | Copper-core cross-linked poly-insulated, copper strip shielded, halogen-free, low-smoke flame-retardant control cable | ||
| WDZ-KYJYP2-23 | Copper-core cross-linked poly-insulated, copper tape shielded, steel tape armored, halogen-free, low-smoke, flame-retardant control cable | ||
| WDZ-KYJY33 | Copper-core cross-linked poly-insulated, fine steel wire armoured, halogen-free, low-smoke flame-retardant control cable | ||
| WDZN-KYJY | Copper-core cross-linked poly-insulated, halogen-free, low-smoke flame-retardant, fire-resistant control cable | ||
| WDZN-KYJYP2 | Copper-core cross-linked poly-insulated, copper tape shielded, halogen-free, low-smoke flame-retardant control cable | ||
| WDZN-KYJYP2-23 | Copper-core cross-linked poly-insulated, copper tape shielded, steel tape armored, halogen-free | ||