The AFDD-63 ArcFault Circuit Breaker (AFCI, also known as AFDD ArcFault Detector) technology is a circuit protection product. Its primary function is to detect and differentiate dangerous ground arc faults, parallel arc faults, and series arc faults, and promptly activate the device to interrupt the current to prevent electrical fires. In the event of an arc fault, due to the relatively low current strength, which is below the set values of overcurrent protection widely installed in the power system, especially in the low-voltage distribution field, installing an AFCI fault arc circuit breaker at the distribution line terminal can promptly detect and cut off the circuit, effectively reducing the losses caused by the arc.
Product Features
If "spark" or arc occurs in the circuit, immediately disconnect the power supply to effectively reduce losses.
Support custom-made residual current protection
Left zero, right fire; left fire, right zero; or double break point - three types of break point methods
Track installation, enhance work efficiency
Utilizing fire-retardant materials to enhance system safety.
Protective Functions
Capable of promptly cutting off the power supply to short-circuit, overloading, arc, and leakage faults in the load supply lines
Technical Specifications
| Performance | Parameters | |
| Meets standards | IEC/EN62606,IEC/EN61009,GB/T31143-2014,GB14048.2 | |
| Rated Operating Voltage | AC230V/AC110V | |
| Rated Frequency | 50Hz/60Hz | |
| Rated Current (ln) | 6,10,16,20,25,32,40,50,63A | |
| Extreme Number | 1P/2P | |
| Rated Impulse Withstand Voltage Uimp | 4KV | |
| Rated short-circuit breaking capacity | 4.5KA | |
| Rated Disconnection Current In | 10mA to 50mA adjustable | |
| Rated Non-Release Current Ino | 0.5ln | |
| Detent Curve | 0.5ln | |
| Action Type | Instant, Delayed, Selective | |
| Leakage type | AC,A | |
| Overvoltage adjustable range | 250-280V | |
| Under-voltage adjustable range | 180-120V | |
| Contact Information | RF2.4G CAN BUS | |
| Basic Protection Features | Capable of promptly cutting off the power supply to short-circuit, overloading, arc, and leakage faults in the load supply lines | |
| Additional features and specifications | Equipped with LED status indicator, fault memory, load (LED indicator when >2A), and leakage warning function. Capable of wireless networking and energy management. | |
| Service Life | Electrical lifespan | ≥3,000 operating cycles |
| Mechanical lifespan | ≥10,000 operating cycles | |
| Protection Grade | IP20 | |
| Protection Grade (within the distribution box) | IP40 | |
| Operating Temperature | -20℃~+45℃ | |
| Store at transport temperature | -35℃~+60℃ | |
| Termination Wire Capability | 1-25mm2 | |
Application Scope
Fault Arc Protection Devices are suitable for electrical lines in industrial and residential buildings with power ratings of 10KW or less, with the protected line length not exceeding 100 meters. They are applicable to nursing homes, schools, commercial buildings, hotels, factories, warehouses, libraries, offices, and residential homes.