Three-phase current limiting protector, effectively overcoming the issues of large short-circuit current, long time for cutting off short-circuit current, large arc sparks during short-circuit, and rapid limiting of short-circuit current with a microsecond speed during lifespan failure to achieve arc protection. Rated current: 0-80A, widely used for line protection in the end and branch circuits of various power supply places such as school dormitories, hospitals, shopping malls, hotels, warehouses, residential areas, electric vehicle charging stations, and marketplaces.
Product Features
Short-circuit breaking capacity: 0.00015 seconds
Real-time measurement of current magnitude
Fan design, to prevent equipment overheating
Track installation, enhance work efficiency
Application fields cover various sectors.
Feature Description
Fault protection function: In the event of a product malfunction, a fault indicator will be activated, and the self-protection function will be initiated.
Overload Protection Function: Cuts off the overloaded circuit after continuous overload for 3 seconds to prevent fires caused by overload.
Short-circuit protection function: Cuts off the circuit power within 150 microseconds when a protected distribution circuit experiences a short circuit, preventing fires caused by the short circuit.
Real-time current measurement function: Measures the current magnitude in the protected distribution circuit in real time.
Communication Function: Supports connection to electrical fire monitoring equipment for remote monitoring.
Real-time temperature measurement feature: Monitors the cable temperature within the protected power distribution circuit in real time. If the cable temperature exceeds the set threshold, an alarm message is sent to the host computer, and the alarm status remains until reset.
Technical Specifications
| Technical Specifications | Index | |
| Rated Voltage | AC220V/50Hz | |
| Work schedule | On-site power supply, 24/7 operation | |
| Power Consumption | Self-consumption power ≤ 3W (no load) | |
| Port rate | $9,600 (default) | |
| Communication Method | RS485 | |
| Communication Protocol | MODBUS-RTU | |
| Work Environment | Workplace | Areas with weatherproof and dustproof conditions |
| Ambient Temperature | -25℃~+50℃ | |
| Relative Temperature | 10% to 95% (non-caking) | |
| Poster height | No more than 5,000 m | |
Dimensions and wiring diagram
Guide rail: Length 155mm x Width 108mm x Depth 70mm
、
Wiring diagram