FEBUS A1-R | Distributed Fiber-Optic Acoustic Sensing System
Distributed Fiber-Optic Acoustic Sensing Equipment
Vibration Monitoring
Single-end measurement
Phase and Amplitude Monitoring
Easy to install and use
A choice under stringent conditions
As needed, software and interface development.
Advantages Overview
The FEBUS A1-R Distributed Fiber Optic Acoustic Sensing System provides acoustic information at intervals of every 2 meters (typical value) along the kilometers of fiber optic infrastructure deployed. The FEBUS A1-R equipment can also be directly connected to existing fiber optic cables. It only requires that the fiber be single-mode. This system is specially designed and developed, particularly suitable for harsh environments and one-end measurement requirements. Additionally, we offer personalized customization services for the FEBUS A1-R.
Site Inspection
Fiber Deployment (via experienced partners)
• Customized analysis modules and user interfaces as per requirement
• For use with SCADA or similar systems
• 2-year warranty and optional maintenance plans
Wide application range
The FEBUS A1-R Distributed Optical Acoustic Sensing System is an ideal device for many infrastructure monitoring applications, such as:
Pipe, riser, and oil outlet leakage monitoring
Oil Well Safety (Fracture Monitoring, Flow Monitoring)
Vertical Seismic Analysis
Perimeter Security (Intrusion Detection)
Railway Track/Railway Locomotive Safety Monitoring
Undersea Cables (Impact Testing, Electrical Partial Discharge)
Features and Performance Parameters
|
Performance Parameters |
Type |
Phase (Quantitative Acoustic Sensing) |
|
Self-noise |
10 pico strain(Slight Adaptation) |
|
|
Measure Distance |
50 km |
|
|
Spatial resolution (measurement length) |
1 m to 50 m |
|
|
Sample interval |
0.4 m to 50 m |
|
|
Detection Frequency |
50 kHz at 1 km Cable Length |
|
|
2.5 kHz at 20 kmFiber Optic Cable Length |
||
|
1 kHz at 50 kmFiber optic cable length |
||
|
< 0.1 Hz Reliable (Micro-Vibration) |
||
|
Optical Properties |
Sensor Configuration |
Single-endConnect only one end of the fiber, no specific terminal module required.) |
|
Fiber Optic Requirements |
Single-mode Fiber Optic Cable |
|
|
Fiber optic interface |
E2000/APC |
|
|
Technical Data |
Operating System |
Linux (CentOS based) |
|
Communication Interface |
Ethernet |
|
|
Data storage space |
Multiple1 TBOption: External20 TB RAID10Data Storage |
|
|
Data Transmission Protocol |
MODBUS, FTP, interoperability with other parties SCADA interoperability with other parties SCADA |
|
|
Display |
HDMI, DVI |
|
|
External Interface |
USB x6 |
|
|
Power Consumption |
500 W |
|
|
Size |
19 ” / 4 U |
|
|
Weight |
15 kg |
|
|
Environmental Conditions |
Operating Temperature Range |
5 °C to +40 °C, 80 RH -40 °C to + 40 °C (Option: ET Version) |
|
Storage temperature range |
-10 °C to +60 °C |