Integrated Digital Temperature TransmitterSIL2 Temperature Transmitter, SIL Certified Temperature Transmitter
Integrated Digital Display Temperature TransmitterUtilizing silicone rubber or epoxy resin sealing structure, it is shock and moisture-resistant, suitable for installation and use in harsh field environments. Field installation is used within thermocouple and thermistor terminal boxes, directly outputting 4-20mA and 0-10mA signals. This not only saves on expensive compensation wire costs but also enhances anti-interference capability during long-distance signal transmission; the thermocouple transmitter features an automatic cold junction compensation function.
Integrated Digital Display Temperature TransmitterHigh precision, low power consumption, wide operating temperature range, stable and reliable performance; versatile applications, can be integrated with thermocouples and resistance thermometers for field installation, or used as a functional module in detection equipment and instrument panels.
Integrated Digital Display Temperature TransmitterThe DDZ series instrument's on-site installation temperature transmitter unit, used in conjunction with industrial thermocouples and resistance thermometers, employs a two-wire transmission system (two wires serving as a common transmission line for power input and signal output). It converts industrial thermocouple and resistance thermometer signals into linear output signals of 4-20mA or 0-10mA, corresponding to input or temperature signals.
SIL2 Temperature Transmitter可直接 installed within the junction boxes of thermocouples and resistance thermometers, forming an integrated structure. As a new-generation temperature measurement instrument, it is widely applicable in industries such as metallurgy, petroleum, chemicals, power, light industry, textiles, food, and scientific research.
SIL Certified Temperature TransmitterIntelligent temperature transmitters can communicate with host computers via HART modems or remotely manage, configure, monitor variables, calibrate, and maintain the transmitter's model, scale, and range using handheld devices and PCs.
Input Signal: Thermocouples: K, E, J, B, S, T, N.
Output Signal: 4-20mA, 0-10V, FF bus, optional RS485 communication
Basic Error: 0.5%FS, 0.2%FS, Intelligent Type 0.2%FS.
Wiring Methods: 2-wire, 4-wire
Display Mode: The four-digit LCD shows the field temperature. The intelligent four-digit LCD can be set via a PC or handheld device to display any of the following parameters: field temperature, sensor value, output current, or percentage ratio.
Working Voltage: 12V-45V, Nominal Working Voltage: 24V