Purpose and Features:
The HG30-E Multi-functional Calibration Instrument (Tri-Function Meter Calibrator) is suitable for verifying and calibrating various current and voltage meters below 0.2 class. It can also serve as a high-stability test power supply, when paired with high-grade standard meters, to calibrate current and voltage meters above 0.2 class.
2. Key Features:
2.1, 5 1/2-digit LED digital display for output quantity.
2.2 Output current range for AC and DC: 0~50uA~5mA~50mA~500mA~2A~10A
2.3 Output voltage range for AC and DC: 0~500mV~5V~50V~250V~500V~1000V
2.4 The available frequencies for selection are three: 50Hz, 60Hz, 400Hz
2.5 Output overload protection with automatic shutdown and manual reset.
2.6. Each voltage and current level can withstand an overload of 10%.
2.7 Clamp Meter Measurement: Equipped with our standard coil, capable of measuring AC 0~1000A; DC 0~1000A with an error of ±0.3%.
3. Technical Performance
4.1 Stability: DC < 0.01% of full scale / 2 minutes
AC < 0.03% of full scale / 2 minutes
4.2, Distortion of Communication: <0.5%
4.3 DC Ripple Factor: <0.1%
4.4 Output Frequency and Accuracy: 50Hz, 60Hz, 400Hz, <1%
4.5 Output Voltage and Current Range and Accuracy (at 23℃±2℃, output values exceeding 10% of the range)
Export Items | Output Range | Rated Output | Peak Output | Accuracy | |
AC/DC
Voltage | 0~500mV | 10mA | 30mA | DC: ±(0.02% of reading + 0.03% of full scale) AC: ±(0.03% of reading + 0.05% of full scale) | |
0~5V | 20mA | 60mA | |||
0~50V | 40mA | 100mA | |||
0~250V | 20mA | 60mA | |||
0~500V~1000V | 10mA | 30mA | |||
AC/DC Electric Current | 0~50uA~5mA~50mA | DC:3V AC:36V | DC: ±(0.02% of reading + 0.03% of full scale) AC: ±(0.03% of reading + 0.05% of full scale) Below 2mA, accuracy is not assessed. | ||
0~500mA | DC:3V AC:12V | ||||
0~2A~10A | 2V | ||||
Standard Resistance | 10、50、100、 500(Ω) 1K、50K、100K、500K、 1M、10M、20M、 |
0.25W |
±0.3%+20mΩ |
4.6 Power Consumption: AC power voltage 220V±10%, frequency 50Hz±1Hz; power consumption < 180VA
4.7 Work Environment: Temperature in the working environment should be between 5°C and 35°C, with relative humidity not exceeding 80%.
4.8 Work Hours: Continuous
4.9 Dimensions: 135×400×360mm³
4.10 Weight: Approximately 12kg