One, Surge arresters are essential electrical equipment in power grids, protecting electrical equipment from overvoltage damage. Their proper functioning directly impacts the safety of the power system. Typically, surge arresters are monitored using surge arrester monitors, which detect their operation and leakage current. Due to poor sealing, monitors may enter moisture or humidity during operation, causing internal components to rust, or for other reasons, the monitor's counter may not operate normally, leading to inaccurate leakage current readings. Therefore, the "Regulation" stipulates that surge arrester monitors should be inspected annually.1Next.
To meet the production needs of the power system, our company has developedYD-CJCQ-1000KVHigh-voltage surge arrester online monitor testing device. This instrument utilizes both alternating220VPower charging, AC-free220VTest using the built-in rechargeable battery under power conditions. It can both verify the monitor's action counter and check the monitor's leakage current meter. Very easy to use.
II. Product Features
1、 Surge arrester monitor operation test
2、 Test lightning arrester leakage current meter indicator
3、 Automatic Charging Feature
4、 Wide application range: Suitable for the verification of surge arrestor monitors of various models, mainly used for testing online monitoring of extra-high voltage surge arrestors.
5、 Simple to operate, no training required, ready to use right out of the box
6、 Lightweight, suitable for field work
III. Technical Specifications
1、 Range:0-50mAAdjustable
2、 Operating Voltage:AC 220VOr12VBuilt-in rechargeable battery
3、 Sensitivity:1mA
4、 Measurement Error:±2%
5、 Display Method: Pointer Gauge Display
6、 Work Methods: Indoor, Outdoor
7、 Response Time: Instantaneous
8、 Cable Length: Standard3m
9、 Specs and Dimensions:35cm×55cm×27cm
10、 Weight: Approximately5Kg
Section 4: Operating Instructions
1、 Surge Arrester Online Monitor Current Test:
Firstly, insert the output line into the steady-state current output terminal (red and black lines into the corresponding color sockets, with the red line connected to the top of the online monitor and the black line to the bottom). Connect them to the upper and lower ends of the surge arrester monitor, then turn on the steady-state current power switch, manually adjust the current control knob, and compare the monitor's leakage current meter reading with the leakage current indicator value of the tester. If the leakage current meter reading of the monitor matches the adjusted value in the calibration instrument, it indicates that the surge arrester monitor's leakage current meter is functioning properly. Close the steady-state current test switch.
2. Surge Arrester Online Monitor Leakage Trip Test
Change the output wire to the counter test terminals (red and black wires inserted into the corresponding color sockets, and the red wire connected to the top of the online monitoring, the black wire to the bottom of the online monitoring), then turn on the counter test switch. Manually adjust the current adjustment knob until the voltmeter displays2KV-2.5KVOn the left, pressing the discharge button completes a single discharge trigger, and the corresponding online monitor's count increments by one. This indicates that the surge arrester monitor's counter is functioning properly. Proceed to the next action test. Interval between action trigger button presses3—5SAlright. The action is momentary, do not hold for too long. Turn off the power after testing.
3、 Instrument Charging Instructions
At the instrument's connection220VWhen in use, the instrument automatically charges. The red light indicates charging, and the green light indicates fully charged. Make sure it is fully charged before each use!
Summary: If the monitor operates normally under the first two conditions, it indicates the monitor is functioning properly and no replacement is needed. Otherwise, a replacement lightning rod monitor is required.
V. Attachments
1、 System accessories
The system is primarily composed of the following components: the main unit of the verification instrument.220VCharging power cable, test cable3m 2Root.
2、 Maintenance and care
1) This product is a precision instrument; do not open it at will.
2) This product should be stored in a dry, low humidity, and dust-free environment.
3) Please recharge before powering off after a long period of non-use.2Approximately an hour. To ensure the electrical energy after de-energizing
4) This product must not be struck or hit with force.