Class II biological safety cabinet, airflow mode: 30% exhaust and 70% internal recirculation required.
The outer case is made of cold-rolled steel plate with electrostatic powder coating; the operating area features a seamless stainless steel structure on three sides. The washable areas inside are designed with large-radius R corners for easy cleaning. A liquid collection槽 is also provided at the bottom, facilitating cleaning and preventing cross-contamination.
Standard with two ULPA filters, achieving 99.999% efficiency for particles as small as 0.12μm; the filter membrane is made of borosilicate glass fiber without partitions.
The control system features a high-brightness, high-resolution color LCD touch screen display, which real-time shows parameters such as intake wind speed, descent wind speed, sterilization, lighting, etc., along with password modification program settings to prevent accidental operation.
The studio features a negative pressure leak-proof design, enveloping the work area with negative pressure on all four sides, truly achieving zero leakage to ensure the cleanliness of the operation area.
The fan is equipped with voltage fluctuation compensation and resistance sensing compensation, effectively extending the lifespan of the filter.
Utilizes ultra-micro pressure difference wind speed sensor for real-time wind speed detection.
Temperature Sensor: Allows for real-time detection and display of temperature.
Equipped with filter pre-failure, damage, and blockage alarm technology, timely reminders for filter replacement.
Equipped with a height alarm device, it alerts users with sound and light when the sliding glass door is below or above the specified height limit.
Features include预约sterilization and sterilization timing function, with accumulated running time of the sterilization lamp and filter operation time recorded. It also includes a reminder to replace the ultraviolet lamp after over 2000 hours of accumulated running time (running time can be set manually).
Integrated front window sliding door, capable of being positioned anywhere and can be fully closed for sterilization. The front glass door is made of safety tempered glass with a thickness of not less than 5mm.
Front window interlock with sterilization lamp design: The sterilization lamp turns off when the front window is opened, ensuring safety for the experimenter and the experimental samples.
Parameters with memory protection against power outages and system crashes, with power-on recovery function.
The front intake port features a design with unobstructed return airflow, ensuring effective prevention of backflow during operation and enhancing safety.
10-degree tilt design for enhanced ergonomics and operator comfort.
In-cabinet Power Supply: Waterproof socket design for greater flexibility and convenience in operation.