Jiangsu Du'an WDS100-160 Horizontal Centrifugal Pipeline Pump
Horizontal Centrifugal Pump CAD Installation Drawing
Product Pump Variable Frequency Control
Flow Rate: 100 cubic meters per hour
32-meter lift height
Motor Power: 15 kW
Impeller speed: 2900 RPM
Cast Iron
Variable Frequency Drive Motor




Duwan WDS100-160Single-stage centrifugal pipelinePump rated parameter tolerances, vibration intensity during normal operation, noise values, etc., should all comply with the standard specifications required by the product. Distance from the pump1 Noise level at 3 meters below85dBVibration values meetStandard Requirements。
WDS100-160Single-stage centrifugal pipelinePump coating and quality meet the standards of the Ministry of Mechanical and Electrical Engineering, no additional information provided.WillPeeling paint, dents, bulges, and hard scrape marks on the exterior.Phenomenon.Surface painting as perThe equipment itselfStandard colors: Pump in silver, motor in apple green, motor cover in yellow, motor cover with red directional mark, coupling guard in yellow.
WDSSingle-stage centrifugal pipelineThe pump operates smoothly without any sticking or hesitation. All exposed rotating parts are equipped with detachable protective covers.
WDSSingle-stage centrifugal pipelinePump main materials:
Pump Housing:Cast IronOr equivalent
Propeller:Cast IronOr equivalent
Spindle:Cast IronOr equivalent
Abrasion-resistant lining:Cast IronOr equivalent
Shaft Seal: Mechanical Seal
Manufacture, inspect, test, and accept
(1Each pump must pass inspection and testing, and be accompanied by a product certification and user manual before it can be shipped.
(2Material testing should include chemical composition tests, mechanical property tests, non-destructive tests, etc.
(3Pump testing and inspection include:
a.Water Pressure Test
Pressure-bearing parts(Pump bodies, pump covers, and sealing end caps, including fasteners)The test pressure should be equal to the basic design pressure.1.5 Double the hydrostatic test pressure. The test should be conducted using cold, clean water, and the pressure should be maintained for at least10 Minute, no visible leakage.
b.Performance Test
·Hydraulic testing andNPSH Tests should be conducted according toJB3562 Standard procedures
·Vibration test as perJB/TQ380 Standard procedures
·Noise test conductedJB/TQ381 Standard procedures
·Inspect bearing temperature<80℃
·Leakage Test of Sealed Containers
c.Inspect
·Inspection of Components Before Assembly
·Internal inspection of the pump body and sealing ring after trial operation
·Dimension inspection for installation
·Inspection of auxiliary piping and other accessories
·Overall appearance inspection(Including label data, surface paint, packing list, random documents, and accessories.) ·Operational status inspection(Including steering)
Jiangsu Du'an Environmental ProtectionWDSHorizontal CentrifugalPump factory-fittedMaterials:
Country of Origin, Equipment Manufacturer, and Full Name of Manufacturer
Form, model, specifications, external dimensions, technical performance, and relevant parameters of the equipment
Basic bolt layout detail and civil load
Pump assembly general layout drawing
Pump Assembly Structural Diagram
Detailed technical specifications
Part Material and Protective Coating Description
Dimensions and space requirements for the equipment's shape, installation, and maintenance operation.
Electrical schematic diagrams and terminal wiring diagramsØ Control Schematic
Manual or Equipment List
Centrifugal Pump Technical Data Sheet
Supplier List (including name, quantity, specifications, performance parameters, material, origin)
Installation, operation, and maintenance manuals for equipment (provided after contract signing)