K-Type High Temperature Thermocouple Compensation Wire ZR-KX-H-YVRP Multi-strand Shielded Temperature Measurement Wire;
Terms of Use
Operating Temperature:
Thermal resistance: two types available, up to 200℃ and 260℃. General use: two types available, up to 70℃ and 105℃.
2. Lowest environmental temperature:
Fluoroplastic insulated and sheathed cables: Fixed installation - 60°C, non-fixed installation - 20°C. Polyvinyl Chloride insulated and sheathed cables: Fixed installation - 40°C, non-fixed installation - 15°C.
3. Allowable Bend Radius:
a) Compensation cables with copper tape shielding should not be less than 16 times the cable's outer diameter; b) Compensation cables with other structures should not be less than 10 times the cable's outer diameter.
Model, Name
Compensating Wire
Model | Name |
KX-GS-VV | PVC insulated and sheathed cables are commonly used with precision K-type thermocouple compensation wires. |
KX-GS-VPV | Polyvinyl Chloride insulated and sheathed copper wire braided shielding, generally used with precision K-type thermocouple, shielded compensation wires. |
KX-HS-FF | High-temperature compensation wire for precision K-type thermocouples, suitable for fluoroplastic insulation and sheath, and heat-resistant applications. |
KX-HS-FP1F | Fluoroplastic insulated and sheathed tin-plated copper wire braided shielding, high-temperature compensation wire for precision grade K thermocouple with high-heat resistance. |
KX-HS-FB | PTFE insulated, glass fiber braided sheath, high-temperature compensating wire for precision K-type thermocouples. |
KX-HS-FBP1 | PTFE tape insulated glass fiber braiding, tin plated copper wire braiding shield, glass fiber braiding outer sheath, high-temperature compensation wire for precision K-type thermocouples. |
KX-HS-FP1V105 | Fluoroplastic insulated tin-plated copper wire braid shield, heat-resistant up to 105°C, with a PVC sheath for high-temperature compensation wires used in precision K-type thermocouples. |
Note: The model representation of standard-grade compensation wire is obtained by removing the letter "S" from the precision-grade compensation wire model (same applies).


Compensation Cable
Model | Name |
KX-GS-VV | PVC insulated, twisted pair PVC sheathed cables are commonly used with precision-grade K type thermocouples and compensating cables. |
KX-GS-VPV | PVC insulated, twisted pair copper wire braid shielded, with PVC sheath, typically used with precision grade K-type thermocouple compensating cables. |
KX-GS-VPVP | PVC insulated twisted copper wire braided with both partial and total shielding, PVC sheath typically used with precision-grade K-type thermocouple compensation cables. |
KX-GS-VVP | PVC insulated twisted copper wire braided overall shielding with a PVC sheath is commonly used for precision grade K type thermocouple compensation cables. |
KX-HS-FF | High-temperature compensation cable for precision K-type thermocouples, with fluoroplastic insulated and sheathed twisted fluoroplastic wire |
KX-HS-FP1F | Fluoroplastic insulated twisted pair tinned copper wire braid shielded fluoroplastic sheath precision grade K thermocouple with high temperature compensation cable |
KX-HS-FP1FP1 | Fluoroplastic insulated twisted-pair tin-coated copper wire braid, with both individual and overall shielding, for precision K-type thermocouple applications with high-temperature compensation cables. |
KX-HS-FFP1 | Fluoroplastic insulated twisted-pair tinned copper wire braided overall shielded fluoroplastic sheathed precision K-type thermocouple high-temperature compensation cable |
KX-HS-FV105 | Fluoroplastic insulated thermally resistant 105°C PVC sheathed cable, high precision K-type thermocouple compensation cable |
KX-HS-FP1V105 | Fluoroplastic insulated twisted-pair tin-coated copper wire braid shielded, heat-resistant up to 105°C, PVC sheathed, precision grade K thermocouple compensation cable |
KX-HS-FP1V105P1 | Fluoroplastic insulated, tin-plated copper wire braided, overall shielding, heat-resistant up to 105°C, PVC sheathed, precision grade K thermocouple with high-temperature compensation cable |
KX-HS-FV105P1 | Fluoroplastic insulated, tin-plated copper wire braided overall shielding, heat-resistant up to 105°C, PVC sheathed, precision grade K thermocouple compensation cable |
Note:
1. Other model compensation wires such as KC, JX, SC, EX, NC, TX, etc., only need to modify the * item of the model, such as EX-G-VV, TX-H-FVP, etc.
2. When the conductor requires multiple soft cores, append "R" after the original model number, e.g., TX-G-VVPR.
3. We also offer insulation-compensating cables with polyethylene (Y) insulation or cross-linked polyethylene (YJ) insulation as required.
4. The shielding layer of the compensating cable can also be wrapped with metal tape, such as: composite aluminum tape (P3), composite copper tape (P2).
5. Flame-retardant compensating cables are required, and "ZR-" should be added before the original model number.
6. Required armored compensating cables should be marked with “-22” after the original model number to indicate steel tape armor; “-32” for steel wire armor.
ZR-KX-H-YVRP K-Type high-temperature thermocouple compensating wire; multi-strand shielded temperature measuring wire