Compensating wire K-type KX-H-FV-2*1.5 thermocouple temperature sensing extension cable.
Detailed Explanation of Thermocouple Compensation Wire, Structure and Definition: Thermocouple compensation wire, commonly referred to as compensation wire, is typically composed of compensation wire alloy wire, insulation, sheath, and shielding layer. Within a certain temperature range (including room temperature), it consists of a pair of insulated wires with a nominal electromotive force (emf) value identical to that of the matched thermocouple. These wires are used to connect the thermocouple to the measuring device to compensate for the temperature variations at the connection point with the thermocouple, thereby reducing errors.
Two: The use of compensating cables between thermocouples and measuring devices offers two advantages:
1. Enhance the physical and mechanical properties of thermocouple temperature measurement lines. Using multi-strand cores or small-diameter compensating wires can improve the flexibility of the lines, facilitate wiring, and also adjust line resistance or shield external interference.
2. Reduce the cost of measurement circuitry; when the thermocouple is far from the measuring device, the use of compensating cables can save a significant amount of thermocouple material, especially when using precious metal thermocouples, where the economic benefits are more pronounced.


Section 3: Terms and Symbols:
(1) Extended Compensation Wire: Also known as extended wire, the extended compensation wire has the same nominal chemical composition of the alloy wire and electromotive force (EMF) nominal value as the thermocouple it is paired with. It is indicated by the letter "X" appended after the thermocouple type, e.g., "KX" indicates an extended compensation wire for a K-type thermocouple.
(2) Compensation Compensation Wire: Also known as compensation wire, the nominal chemical composition of the alloy wire in the compensation wire is different from that of the thermocouple it is paired with. However, its electromotive force value is the same as the nominal value of the electromotive force of the paired thermocouple at 0-100℃ or 0-200℃. It is indicated by the letter "C" appended after the thermocouple type number, such as "KC". Different alloy wires can be applied to the same type number of thermocouples and distinguished by additional letters, such as "KCA", "KCB". Currently, it is not widely used.
(3) Tolerance: The tolerance of the thermocouple compensating cable is due to significant deviations caused by the compensating cable in the measurement system. This value is expressed in microvolts, with two levels of tolerance: precision grade and standard grade.
(4) Symbols: S - indicates precision class thermocouple compensation wire. No letter is marked for general class compensation wire; G - indicates general use compensation wire; H - indicates heat-resistant compensation wire; R - indicates compensation wire with multi-strand core. No letter is marked for single-strand core compensation wire; P - indicates compensation wire with a shielding layer; V - indicates insulation or sheath made of polyvinyl chloride (PVC); F - indicates insulation made of polytetrafluoroethylene; B - indicates sheath made of non-glass fiber material.
KX-HA-FFRP Fluoroplastic烯绝缘 and sheath copper wire braid total shielding precision grade K thermocouple compensation flexible cable
KX-HA-FPFP Fluoroplastic Insulated and Sheathed Copper Wire Braided Screen Summed Precision Class K Thermocouple Compensation Cable
KX-HA-FPFRP Fluoroplastic Insulated and Sheathed Copper Wire Braid Screened Precision K Type Thermocouple Compensation Flexible Cable
KX-HA-FVP Fluoroplastic烯Insulated PVC Sheath Copper Wire Braid Overall Shielded Precision Class K Thermocouple Compensation Cable
KX-HA-FVRP Fluoroplastic烯绝缘PVC sheathed copper wire braid overall shield precision K type thermocouple compensating soft cable
KX-HA-FPVP Fluoroplastic Insulated PVC Sheathed Copper Wire Braid Screened Precision Class K Thermocouple Compensation Cable
KX-HA-FPVRP Fluoroplastic insulated polyvinyl chloride sheath copper wire braid split-screen total shielding precision grade K thermocouple compensation flexible cable
KX-HA-FGP Fluoroplastic烯绝缘 Silicon Rubber Sheathed Copper Wire Braid Total Shielded Precision Class K Thermocouple Compensation Cable
KX-HA-FGRP Fluoroplastic烯Insulating Silicone Rubber Sheathed Copper Wire Braid Total Shield Precision Grade K Thermocouple Compensation Flexible Cable
KX-HA-FPGP Fluoroplastic Insulated Silicone Rubber Sheathed Copper Wire Braid Screened Summation Shielded Precision Class K Thermocouple Compensation Cable
KX-HA-FPGRP Fluoroplastic Insulated Silicone Rubber Sheathed Copper Wire Braid Screening, Precision Grade K Thermocouple Compensating Flexible Cable
KX-FP3F Fluoroplastic Insulated Aluminum/Plastic Composite Tape, Shielded Fluoroplastic Sheath, Standard Grade K Type Thermocouple Compensation Cable
KX-FP3FP3 Fluoroplastic Insulated Aluminum/Plastic Composite Tape, Shielded and Overall Shielded Fluoroplastic Sheath, Standard Grade K Type Thermocouple Compensation Cable
KX-FFP3 Fluoroplastic Insulated Fluoroplastic Sheathed Copper Wire Braid Aluminum/Plastic Composite Tape General Grade K Type Thermocouple Compensation Cable
KXS-FP3F Fluoroplastic Insulated Aluminum/Plastic Composite Tape, Shielded Fluoroplastic Sheath Precision Class K Thermocouple Compensation Cable
KXS-FFP3 Fluoroplastic Insulated and Sheathed Aluminum/Plastic Composite Tape, Total Shielding Precision K Type Thermocouple Compensation Cable
KXS-FP3FP3 Fluoroplastic Insulated Aluminum/Plastic Composite Tape, Shielded and Total Shielded Fluoroplastic Sheathed Precision Class K Thermocouple Compensation Cable
Compensating Wire Type K, KX-H-FV-2*1.5 Thermocouple Sensing Temperature Line Extension ;
Note: The above basic models list the shielding methods for copper wire or tin-plated wire only; other shielding types can be changed by simply altering the shielding code, such as adding "ZR" before the model number for flame-retardant types P2, P3, adding "22" after the model number for armored cables, ZR192 is made of imported PFA material, with a temperature resistance of 260°C.