Heater Roll Welding Machine Operation Instructions
1、 Working Voltage: Three-phaseAC380V +10% ,50Hz + 1%。
2、 Work Environment:No frost at 0-45℃; no condensation at humidity ≤ 85%.
3、 Maintenance: Add lubricating conductive grease per shift3 times; clean the water circulation filter daily; clean the water tank sediment every 3 days; change the water every 20 days; use pure water for cooling in summer and antifreeze fluid in winter; replace the transmission gear oil once a month; dust collection and cleaning daily.
4、 Operation Method: After selecting the processing specifications, the welder automatically applies pressure, rotates, welds, and stops when the foot pedal switch is closed. The work stops when the foot pedal switch is released, and all actions are disconnected.
5、 Protective spark splash gear must be worn at all times to prevent personal injury.
6、 Welding machines generate high temperatures, causing the conductive copper wheels to wear over time. If the copper wheels deform, accumulate slag, or require correction during use, they should be replaced or adjusted promptly.
7、 Cooling Machine Operating Voltage: Three-phase, four-wireAC380V + 10% ,50Hz + 1%。
8、 Chiller operates normally during operation.Perform Freon topping up every 3 months.
9、 Extended downtime, please drain the water from the water-cooled unit to ensure the chiller is dry.
10、 High-pressure gauge less than2.6mpa。
11、 Low rolling gauge0.2mpa。
12、 In case of other emergencies, please shut off the power and contact the person in charge.